Dwyer Series AT-MS | ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter | 4-20 mA (2-wire)
The Dwyer Series AT-MS is an ATEX/IECEx approved magnesense® differential pressure transmitter range, built to order. Contact us with the options you need for a quotation.
The Series AT-MS ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter is an extremely versatile transmitter for monitoring pressure and air velocity in hazardous areas. This transmitter is loaded with features such as: field selectable English or metric ranges, field upgradeable LCD display, adjustable dampening of output signal and the ability to select a square root output for use with pitot tubes and other similar flow sensors.
- Service: Air and non-combustible, compatible gases
- Wetted Materials: Consult factory
- Accuracy: MS-X21: 0.5 in w.c. and 0.25 in w.c.: ±1%; 0.1 in w.c.: ±2%; 100
- Pa and 50 Pa: ±1%; 25 Pa: ±2%
- MS-X11: 5 in w.c. and 2 in w.c.: ±1%; 1 in w.c.: ±2%; 1250
- Pa and 500 Pa: ±1%; 250 Pa: ±2% (@ standard conditions)
- Specifications
- Features
| Part Number | Series AT-MS |
| Brand | Dwyer |
| Series | AT-MS |
| Service | Air and non-combustible, compatible gases |
| Wetted Materials | Consult factory |
| Accuracy | MS-X21: 0.5 in w.c. and 0.25 in w.c.: ±1%; 0.1 in w.c.: ±2%; 100 |
| Pa and 50 Pa | ±1%; 25 Pa: ±2% |
| MS-X11 | 5 in w.c. and 2 in w.c.: ±1%; 1 in w.c.: ±2%; 1250 |
| Pa and 500 Pa | ±1%; 250 Pa: ±2% (@ standard conditions) |
| Stability | ±1% FS/year |
| Temperature Limits | 0 to 150°F (-18 to 66°C) (Note: Product temperature limits differ from case) |
| Pressure Limits | 1 psi max., operation; See pressure limit chart for burst |
| Power Requirements | 10-35 VDC (2-wire); 17-36 VDC or isolated 21.6-33 VAC (3-wire) |
| Output Signals | 4-20 mA (2-wire); 0-5 V, 0-10 V (3-wire) |
| Response Time | 300 ms |
| Zero and Span Adjustments | Digital push-button. In safe zone only |
| Loop Resistance | Current output: 0 to 1250 Ω max.; |
| Voltage output | min. load resistance 1 kΩ |
- Service: Air and non-combustible, compatible gases
- Wetted Materials: Consult factory
- Accuracy: MS-X21: 0.5 in w.c. and 0.25 in w.c.: ±1%; 0.1 in w.c.: ±2%; 100
- Pa and 50 Pa: ±1%; 25 Pa: ±2%
- MS-X11: 5 in w.c. and 2 in w.c.: ±1%; 1 in w.c.: ±2%; 1250
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer Series 638R | OEM Pressure Transmitter | 0.5-4.5 VDC ratiometric
Dwyer Series 638R | OEM Pressure Transmitter | 0.5-4.5 VDC ratiometric
Dwyer RPMC-B-003 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-003 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-014 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-014 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer 655A-07-P | Fixed Range Differential Pressure Transmitter | 0 to 2 psid, 4-20 mA DC or 1-5 VDC
Dwyer 655A-07-P | Fixed Range Differential Pressure Transmitter | 0 to 2 psid, 4-20 mA DC or 1-5 VDC