Client Protection
Dedicated Support
Dwyer RPMC-B-003 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
The Dwyer RPMC-B-003 is a StabiliSENSE™ critical room pressure monitor.
The Series RPMC StabiliSENSE™ Critical Room Pressure Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming. The Series RPMC can be configured to monitor positive or negative pressure in protected environments and clean manufacturing areas. The RPMC is a complete system which enables access to pressure, security, calibration, and alarm setup. The RPMC StabiliSENSE™ critical room pressure monitor has a brushed stainless steel bezel that allows for easy cleaning.
- Service: Air and non-combustible, compatible gases
- Measurement Technology: Capacitance cell
- Wetted Materials: Consult factory
- Housing Material: Die cast aluminum case and SS bezel
- Accuracy: ±0.25%
- RSS (includes non-linearity: ±0.24%, hysteresis: ±0.05% and non-repeatability: ±0.05%), or ±0.5%
- Specifications
- Features
| Part Number | RPMC-B-003 |
| Brand | Dwyer |
| Series | RPMC |
| Accuracy | ±0.25% |
| Electrical Rating | 1 A @ 30 VAC/VDC |
| Display | Backlit 4 digit LCD 0.4˝ height LED indicators for set point and alarm status |
| Weight | 1.90 lb (862 g) |
| Service | Air and non-combustible, compatible gases |
| Measurement Technology | Capacitance cell |
| Wetted Materials | Consult factory |
| Housing Material | Die cast aluminum case and SS bezel |
| RSS (Includes non-linearity | ±0.24%, hysteresis: ±0.05% and non-repeatability: ±0.05%), or ±0.5% |
| Pressure Limits | 2 psig |
| Temperature Limits | 32 to 140 °F (0 to 60 °C) |
| Compensated Temperature Limits | 32 to 140 °F (0 to 60 °C) |
| Thermal Effects | 0.030%/°F (0.050/°C) from 77 °F (25 °C) |
| Power Requirements | 12-28 VDC, 12-28 VAC 50 to 400 Hz |
| Power Consumption | 3 VA max |
| Output Signal | 4-20 mA DC into 900 Ω max |
| Zero and Span Adjustments | Accessible via menus |
| Response Time | 8 ms |
| Electrical Connections | 15 pin male high density D-sub connection. 18˝ (46 cm) cable with 10 conductors included |
| Process Connections | 1/8˝ female NPT. Side or back connections |
| Mounting Orientation | Mount unit in vertical plane |
| Size | 4-3/4˝ (120.7 mm) OD x 2-21/32 (67.5 mm) |
| Agency Approvals | CE |
| Switch Type | 2 SPDT relays |
| Set Point Adjustment | Adjustable via keypad on face |
- Service: Air and non-combustible, compatible gases
- Measurement Technology: Capacitance cell
- Wetted Materials: Consult factory
- Housing Material: Die cast aluminum case and SS bezel
- Accuracy: ±0.25%
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer Series 638R | OEM Pressure Transmitter | 0.5-4.5 VDC ratiometric
Dwyer Series 638R | OEM Pressure Transmitter | 0.5-4.5 VDC ratiometric
Dwyer Series AT-MS | ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter | 4-20 mA (2-wire)
Dwyer Series AT-MS | ATEX/IECEx Approved Magnesense® Differential Pressure Transmitter | 4-20 mA (2-wire)
Dwyer RPMC-B-014 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-014 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-A-002 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer RPMC-B-013 | StabiliSENSE™ Critical Room Pressure Monitor | ±0.25%, 4-20 mA DC into 900 Ω max
Dwyer 655A-07-P | Fixed Range Differential Pressure Transmitter | 0 to 2 psid, 4-20 mA DC or 1-5 VDC
Dwyer 655A-07-P | Fixed Range Differential Pressure Transmitter | 0 to 2 psid, 4-20 mA DC or 1-5 VDC