Fluidwell E110 | Explosion proof Flow Logger / Totalizer | with analog and pulse signal outputs, ambient -40°C to +70°C
The E110 is a popular model in our range of explosion proof flow rate indicator / totalizer, complete with pulse and analog output signals. The E-series is distinguished by its high quality manufacturing and its functionality driven European design. We believe, it is not just about fulfilling the requirements for explosion proof, but it is about safety during daily operation. Typical use: Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required.
Key features
- Explosion proof according ATEX, IECEx and CSA C-US.
- Aluminum or high grade stainless steel Ex d enclosure.
- Easy installation with the spacious chamber and plug & play connectors.
- Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
- Key information at a glance as the display shows flow rate, total, accumulated total, measuring units and a flow rate indicating speedometer.
- Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
- 7 digit flow rate / total and 11 digit accumulated total.
- Specifications
- Features
- Downloads
| Part Number | E110 |
| Brand | Fluidwell |
| Product Type | Flow Logger / Totalizer |
| Enclosure / Area | Explosion proof |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA. Output loop-powered.; 9 – 27V DC. |
| Supply - Sensor Supply | 3, 8.2, 12, 24V DC. |
| Signal Inputs - Status Inputs | Remote control: external input for clearing total or to disable manual clearing by the keypad. |
| Signal Outputs - Pulse Outputs | Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons). and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.; Type: One passive NPN transistor and one isolated electro-mechanical relay. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting the flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).; Type: One galvanically isolated, loop powered 4 – 20mA output. |
| Communication | Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction. Type: RS232, RS485 2-wire Modbus RTU or Local USB. Remote configuration via free downloadable remote configuration tool (see dropdown download above). HART communication is available with the E018 Flow rate Monitor / Totalizer. |
| Hazardous Area - Explosion Proof | ATEX: Gas: II 2 G Ex db IIC T6 Gb. Dust: II 2 D Ex tb IIIC T85 °C Db.; IECEX: Gas: Ex db IIC T6 Gb. Dust: Ex tb IIIC T85 °C Db.; CSA C-US: XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D. DIP (Dust-Ignition-proof): Class II, Div. 1, Groups E, F, & G T85 °C; Class III. Gas: Class I, Zone 1, AEx db IIC T6 Gb. Dust: Zone 21, AEx tb IIIC T85 °C Db. |
- In accordance with ATEX, IECEx, FM, and CSA C-US, explosion proof.
- Ex terior enclosure made of premium stainless steel or aluminum.
- Plug and play connectors and a roomy chamber make installation simple.
- Installing a direct flowmeter mounting nozzle with a 1" NPT thread is simple and saves money.
- The display provides important details in a look, including measuring units, flow rate, total, and accumulated total, as well as a flow rate-indicating speedometer.
- Simple engineering unit setup with K-factor for mass or volumetric measurements. Use this interactive tutorial to learn more.
- 11-digit cumulative total and 7-digit flow rate/total.
- LED backlight that is bright.
- The total for the current day (Daily total), the total for the previous day (both non-resettable), and the total for the last 15 days can be shown.
Other models in this series
Click a row to open that product.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Nuflo MC II Analyser | Flow Indicator
Nuflo MC II Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT