Client Protection
Dedicated Support
Dwyer TTE-104-W | Explosion-Proof RTD Temperature Transmitter | 4" Probe
The Dwyer TTE-104-W is an explosion-proof rtd temperature transmitter: explosion-proof RTD temperature transmitter, 4" probe.
- Construction Type: Well Probe
- Current Output: 4 to 20 mA
- Electrical Connection: 1/2 in NPT female Conduit with Screw Terminal block
- Enclosure Ratings: Hazardous Location Rated
- Enclosure Ratings Note: Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1, Groups E, F and G and Class III atmospheres. ATEX Certified: 2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. EUtype Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. IECEx Certified: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31. UKCA Ex Certified for: 0518 II 2 G Ex db IIC T6...T4 Gb / II 1 D Ex ta IIIC T111°C Da, T6 process temp ≤ 80°C, T5 process temp ≤ 95°C, T4 process temp ≤ 120°C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
- Input Note: User selectable – any range between -30 to 250°F with a minimum span of 40°F.
- Specifications
- Features
- Downloads
| Part Number | TTE-104-W |
| Brand | Dwyer |
| Series | TTE |
| Supply Voltage | 10 to 35 Vdc |
| Construction Type | Well Probe |
| Current Output | 4 to 20 mA |
| Electrical Connection | 1/2 in NPT female Conduit with Screw Terminal block |
| Enclosure Ratings | Hazardous Location Rated |
| Enclosure Ratings Note | Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1, Groups E, F and G and Class III atmospheres. ATEX Certified: 2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex ta IIIC T111 °C Da, T6 Process Temp ≤80 °C, Temperature Class T5 Process Temp ≤95 °C, Temperature Class T4 Process Temp ≤120 °C as defined on nameplate. EUtype Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. IECEx Certified: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111 °C Da, T6 Process Temp ≤80 °C, Temperature Class T5 Process Temp ≤95 °C, Temperature Class T4 Process Temp ≤120 °C as defined on nameplate. IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31. UKCA Ex Certified for: 0518 II 2 G Ex db IIC T6...T4 Gb / II 1 D Ex ta IIIC T111 °C Da, T6 process temp ≤ 80 °C, T5 process temp ≤ 95 °C, T4 process temp ≤ 120 °C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. |
| Input Note | User selectable – any range between -30 to 250 °F with a minimum span of 40 °F. |
| Measurement Type | RTD |
| Number of Wires | 2 |
| Operating Temperature, Max | 158 °F |
| Operating Temperature, Min | -4 °F |
| Output Detail | 4-20 mA (2-wire loop powered) |
| Output Signal | Current |
| Pressure Limits | Up to 2000 psi |
| Probe Length | 4 in |
| Process Connection Size | 1/2 in |
| Process Connection Type | NPT Male |
| Process Temperature, Max | 250 °F |
| Process Temperature, Min | -30 °F |
| Protection | Explosion-Proof |
| Response Time | 250 ms |
| Sensor Type | Pt1000 |
| Supply Power Type | DC |
| Thermal Effects | ± 0.02%/°C max |
| Transmitter Accuracy | Transmitter: ± 0.1%, Probe: ± 0.3% |
| Weight | 1134 g |
| Country of Origin | United States |
| probe-length | 4 in |
- Construction Type: Well Probe
- Current Output: 4 to 20 mA
- Electrical Connection: 1/2 in NPT female Conduit with Screw Terminal block
- Enclosure Ratings: Hazardous Location Rated
- Enclosure Ratings Note: Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1, Groups E, F and G and Class III atmospheres. ATEX Certified: 2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. EUtype Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31. IECEx Certified: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process Temp ≤120°C as defined on nameplate. IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31. UKCA Ex Certified for: 0518 II 2 G Ex db IIC T6...T4 Gb / II 1 D Ex ta IIIC T111°C Da, T6 process temp ≤ 80°C, T5 process temp ≤ 95°C, T4 process temp ≤ 120°C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
Other models in this series
Click a row to open that product.
Related Products
Dwyer TXUN-FD | Field-Mount HART Temperature Transmitter | Universal Input
Dwyer TXUN-FD | Field-Mount HART Temperature Transmitter | Universal Input
Dwyer TTE-106-W | Explosion-Proof RTD Temperature Transmitter | 6" Probe
Dwyer TTE-106-W | Explosion-Proof RTD Temperature Transmitter | 6" Probe
Dwyer TTE-109-W | Explosion-Proof RTD Temperature Transmitter | 9" Probe
Dwyer TTE-109-W | Explosion-Proof RTD Temperature Transmitter | 9" Probe
Dwyer TTE-112-W | Explosion-Proof RTD Temperature Transmitter | 12" Probe
Dwyer TTE-112-W | Explosion-Proof RTD Temperature Transmitter | 12" Probe
Dwyer TTE-106-W-LCD | Explosion-Proof RTD Temperature Transmitter | 6" Probe, LCD
Dwyer TTE-106-W-LCD | Explosion-Proof RTD Temperature Transmitter | 6" Probe, LCD
Moore Industries TRY/PRG/4-20mA/10-30DC/-ISA [HPPDN] | TRY PC-Programmable Temperature Transmitter | RTD/T/C/mV/Ohm Input, Isolated 4-20 mA, Intrinsically Safe (ANZEx)
Moore Industries TRY/PRG/4-20mA/10-30DC/-ISA [HPPDN] | TRY PC-Programmable Temperature Transmitter | RTD/T/C/mV/Ohm Input, Isolated 4-20 mA, Intrinsically Safe (ANZEx)
Moore Industries TMZ/TPRG/MB/24DC [DIN] | TMZ MODBUS Temperature Transmitter and Signal Converter | RTD/T/C/mV/Ohm Input, MODBUS RTU RS-485, 24 Vdc
Moore Industries TMZ/TPRG/MB/24DC [DIN] | TMZ MODBUS Temperature Transmitter and Signal Converter | RTD/T/C/mV/Ohm Input, MODBUS RTU RS-485, 24 Vdc