Client Protection
Dedicated Support
Genuine Products
Dwyer RHP-2D2E | Duct Mount RH/Temperature Transmitter | 2% RH, 0-10 VDC RH, 1K Ohm RTD DIN 385 Output
Fitted with a 2% RH sensor, the Dwyer RHP-2D2E duct mount RH/temperature transmitter sends humidity as 0-10 VDC, alongside a 1K Ohm RTD DIN 385 temperature output. This 0-10 VDC, 1K Ohm RTD DIN 385 version is powered from 15-35 VDC or 15-29 VAC and uses a capacitance polymer sensing element with a 15 second response.
- Compensated from -4 to 140°F (-20 to 60°C); removable screw terminal block
- CE marked; humidity signal: 0-10 VDC
- 1K Ohm RTD DIN 385 temperature output
- Supply 15-35 VDC or 15-29 VAC
- Drift under 1% RH per year; hysteresis ±1%; response 15 s
- Specifications
- Features
- Downloads
| Part Number | RHP-2D2E |
| Brand | Dwyer |
| Power | 15-35 VDC or 15-29 VAC |
| Response Time | 15 s |
| Drift | <1% RH/year |
| Mounting | Duct |
| Temperature Output | 1K Ohm RTD DIN 385 (passive) |
| Enclosure Rating | NEMA 4X (IP66), housing |
| Output | 0-10 VDC (RH) |
| Approvals | CE |
| RH Accuracy Class | 2% |
| Sensor | Capacitance polymer |
| Compensated Range | -4 to 140 °F (-20 to 60 °C) |
- Lower installation costs when temperature and humidity are combined.
- With 2%, 3%, and 5% accuracy and a wide range of temperature sensors, there is a wide application environment.
- Lower system operating costs thanks to the radiation barrier that shields the sensor from heat radiation.
Other models in this series
Click a row to open that product.
Related Products
Dwyer A-RH3-1K-NI-O | Outside Air Humidity Transmitter | ±3% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH3-1K-NI-O | Outside Air Humidity Transmitter | ±3% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH3-1K-2W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH3-1K-2W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH3-1K-3W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Three Wires)
Dwyer A-RH3-1K-3W-R | Room Humidity Transmitter | ±3% RH, 1K Ohm RTD (Three Wires)
Dwyer A-RH1-1K-NI-O | Outside Air Humidity Transmitter | ±1% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH1-1K-NI-O | Outside Air Humidity Transmitter | ±1% RH, 1K Ohm Nickel RTD, Euro Enclosure
Dwyer A-RH2-R-LCD-010 | Room Humidity Transmitter with LCD | ±2% RH, 0-10 VDC
Dwyer A-RH2-R-LCD-010 | Room Humidity Transmitter with LCD | ±2% RH, 0-10 VDC
Dwyer A-RH3-R-LCD-010 | Room Humidity Transmitter with LCD | ±5% RH, 0-10 VDC
Dwyer A-RH3-R-LCD-010 | Room Humidity Transmitter with LCD | ±5% RH, 0-10 VDC
Dwyer A-RH2-1K-2W-R | Room Humidity Transmitter | ±2% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH2-1K-2W-R | Room Humidity Transmitter | ±2% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH1-1K-2W-R | Room Humidity Transmitter | ±1% RH, 1K Ohm RTD (Two Wires)
Dwyer A-RH1-1K-2W-R | Room Humidity Transmitter | ±1% RH, 1K Ohm RTD (Two Wires)