Client Protection
    
      
      Dedicated Support
    
        
        Genuine Products
      Dwyer Instruments MARK II 40-1-AV-NIST | Molded plastic manometer | Range 0-1.1" w.c. & 0-4200 fpm | Red fluid | .826 sp. gr. | Requires Pitot tube (*sold separately) | With NIST Calibration certificate
The inclined and inclined-vertical variants of Mark II Molded Manometers are available. The Model 25 gage's curved inclined-vertical tube offers greater ranges at lower readings with easier-to-read increments. Throughout its range, the Model 40 inclined gage offers outstanding resolution and linear calibration. Applications involving air velocity and air filter gage are perfect for the Model 40. Both gage types can measure differential pressure and pressure both above and below atmospheric pressure. Two 4-1/2' pieces of transparent plastic tubing, a plastic swing-out stand, and a leveling screw are included with the Model 40 so that it may be used anywhere. Additionally, it has built-in overpressure safety traps and easy-to-use quick shutoff pressure connections.
- Specifications
 - Features
 - Downloads
 
| Accuracy | Inclined/Vertical: +/-3% FS | 
| Accuracy | Inclined: +/-3% FS | 
| Approvals | Meets the technical requirements of EU Directive 2011/65/EU (RoHS II) | 
| Maximum Operating Pressure | Inclined/Vertical: 10 psi (70 kPa) | 
| Maximum Operating Pressure | Inclined: 15 psi (100 kPa) | 
| Maximum operating temperature | Inclined/Vertical: 140°F (60°C) | 
| Maximum operating temperature | Inclined: 150°F (65°C) | 
| Range | 0-1.1" w.c. & 0-4200 fpm | 
| Scale | Inclined: Approx. 8-1/4" (21 cm) | 
| Series | Mark II Molded Plastic Manometers | 
| Type | Molded Plastic Manometer | 
| Weight | Inclined/Vertical: 1.04 lb (472 g) | 
| Weight | Inclined: 1.23 lb (558 g) | 
- Almost unbreakable thick white styrene-acrylonitrile housing.
 - An overflow tank (Model 25) or float-operated overflow traps (Model 40) can handle moderate overpressures.
 - Able can be fixed in any upright position.
 
Related Products
  
  
Dwyer Instruments 160E-05 | Ellipsoidal tip Pitot tube | 1.22 meter insertion length
  
  Dwyer Instruments 160E-05 | Ellipsoidal tip Pitot tube | 1.22 meter insertion length
  
  
Dwyer Instruments HTDL-30 | High temperature data logger with 24" flexible probe
  
  Dwyer Instruments HTDL-30 | High temperature data logger with 24" flexible probe
  
  
Dwyer Instruments HTDL-20 | High temperature data logger with 2" rigid probe
  
  Dwyer Instruments HTDL-20 | High temperature data logger with 2" rigid probe
  
  
Dwyer Instruments WTDL-20 | Temperature data logger with humidity output
  
  Dwyer Instruments WTDL-20 | Temperature data logger with humidity output
  
  
Dwyer Instruments WTDL-30 | Temperature data logger with probe attachment
  
  Dwyer Instruments WTDL-30 | Temperature data logger with probe attachment
  
  
Dwyer Instruments 472A-1 | Digital input thermocouple thermometer
  
  Dwyer Instruments 472A-1 | Digital input thermocouple thermometer
  
  
Dwyer Instruments DL-8T | 8-channel temperature logger
  
  Dwyer Instruments DL-8T | 8-channel temperature logger
  
  
Dwyer Instruments UDL-114 | Universal data logger with internal temperature and RH sensors | Four universal inputs | LCD display
  
  Dwyer Instruments UDL-114 | Universal data logger with internal temperature and RH sensors | Four universal inputs | LCD display