Client Protection
Dedicated Support
Genuine Products
Dwyer DH-007 | Digihelic Differential Pressure Controller | 10 in w.c. (2.491 kPa)
The Dwyer DH-007 is the 10 in w.c. (2.491 kPa) Digihelic differential pressure controller, a three-in-one instrument with digital display, relay switches and a current-output transmitter. Pressure, velocity or flow operation is selected in a choice of engineering units. Programming on the DH-007 uses a menu key with menus for security level, engineering units, set point control, alarms and digital damping.
- Rated 0.5% full scale accuracy
- Two SPDT relays, adjustable deadband
- Scalable 4-20 mA process output
- Suitable for air and non-combustible gases
- Specifications
- Features
- Downloads
| Part Number | DH-007 |
| Brand | Dwyer |
| Series | DH (Digihelic) |
| Range | 10 in w.c. (2.491 kPa) |
| Output | 4-20 mA |
| Accuracy | 0.5% FS |
| Media | Air, non-combustible gases |
| Port Size | 0.25 in |
| Relays | 2 x SPDT |
- 3-in-1 instrument allows the reduction of several instruments with one product, saving inventory, installation time and money.
- Velocity of flow modes, a square root output coincides with the actual flow curve for greater precision.
- Power usage of 120/220 VAC or 24 VDC provides flexibility to incorporate device in control panel.
- Secure menu program provides access to device operation only for the right skill level.
- Modbus® communications supports Process and HVAC system integration and control.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %