Brannan 10/319/0 | BS 718 S50 Density Hydrometer | 1.55–1.60 g/ml, 190 mm
Part number 10/319/0 identifies the Brannan S50 density hydrometer graduated from 1.55 to 1.60 g/ml to BS 718:1991. On the 10/319/0, graduations fall every 0.002 g/ml over a 0.050 g/ml span, with adjustment at 20 °C and an overall length of 190 mm. The 1.55–1.60 g/ml instrument is UK-made and supplied in a resealable plastic tube for protection.
Key features
- Range 1.55 to 1.60 g/ml
- 0.002 g/ml divisions over a 0.050 g/ml span
- 190 mm overall length, 18–20 mm bulb diameter
- Adjusted at 20 °C
- Soda glass with steel shot ballast and synthetic wax resin
- Made in the UK, supplied in a resealable protective tube
Brannan can supply the 10/319/0 with UKAS certification, a certificate traceable to a recognised national standard, or a statement of conformity.
- Specifications
- Downloads
| Part Number | 10/319/0 |
| Brand | Brannan |
| Series | S50 |
| Standard | BS 718:1991 (generally aligned with ISO 387 and ISO 649) |
| Density Range | 1.55–1.60 g/ml |
| Range Span | 0.050 g/ml |
| Divisions | 0.002 g/ml |
| Overall Length | 190 mm |
| Bulb Diameter | 18–20 mm |
| Approx. Weight | 35 g (incl. 9 g protective tube) |
| Adjustment Temperature | 20 °C |
| Material | Soda glass, steel shot ballast, synthetic wax resin |
| Country of Manufacture | UK |
| Packaging | Protective resealable plastic tube |
Related Products
Brannan 10/635/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.002 div, 250 mm
Brannan 10/635/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.002 div, 250 mm
Brannan 10/634/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 250 mm
Brannan 10/634/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 250 mm
Brannan 10/631/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.001 div, 220 mm
Brannan 10/631/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.001 div, 220 mm
Brannan 10/636/0 | Sea Water Hydrometer | 1.000 to 1.050 g/ml, 0.002 div, 250 mm
Brannan 10/636/0 | Sea Water Hydrometer | 1.000 to 1.050 g/ml, 0.002 div, 250 mm
Brannan 10/630/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 175 mm
Brannan 10/630/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 175 mm
Brannan 10/632/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 200 mm
Brannan 10/632/0 | Sea Water Hydrometer | 1.000 to 1.030 g/ml, 0.002 div, 200 mm
Brannan 10/456/5 | BS 718 S60/60F M50 SP Petroleum Hydrometer | SG 0.90 to 0.95, 270 mm
Brannan 10/456/5 | BS 718 S60/60F M50 SP Petroleum Hydrometer | SG 0.90 to 0.95, 270 mm
Brannan 10/633/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.002 div, 200 mm
Brannan 10/633/0 | Sea Water Hydrometer | 1.000 to 1.040 g/ml, 0.002 div, 200 mm