Barton 7102 RF meter, meter Size :2 inch,End Connection Size :1 inch,Flow Rate :24-240 US GPM
Genuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.
Part No. 7102
Product Overview
The Barton 7102 is a Cameron BARTON Series 7000 liquid turbine flow meter for hydrocarbon measurement. This 2-inch meter covers a flow range of 24–240 US GPM, providing approximately a 10:1 flow range.
Liquid passes through a diffuser onto a multi-blade turbine rotor. The rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.
The Barton 7102 has a listed 1-inch end connection size. The Series 7000 design supports bidirectional measurement, allowing reverse-flow applications without reducing the stated accuracy or capacity.
Rated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.
Before ordering, confirm the required normal and maximum flow rates, meter and line size, end-connection requirements, fluid, pressure rating and compatible electronics. The Series 7000 range is available with flanged and threaded connection configurations, so the required connection should be confirmed for the specific installation.
General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city to confirm availability, compatibility and pricing.
Key Benefits
- Measures 24–240 US GPM in a 2-inch meter
- ±0.25% of reading linearity over the stated flow range
- ±0.15% linearity over limited ranges
- ±0.02% repeatability
- Bidirectional design supports reverse-flow applications
- Sine-wave pickup output for compatible digital readouts, totalizers and flow computers
- Cameron BARTON Series 7000 liquid turbine meter design
- Suitable for hydrocarbon measurement applications
- Free Saudi Arabia shipping available
Who This Product Is Best For
- Oil and gas metering and allocation teams
- Terminal, loading and transfer operations
- Process and instrumentation engineers
- Maintenance teams replacing a like-for-like Barton meter
- Industrial customers requiring a 2-inch liquid turbine meter
- Saudi Arabia buyers sourcing genuine Barton instrumentation
How to Install & Use It
- Confirm that the required normal and maximum flow rates are within the 24–240 US GPM range.
- Verify the meter size, line size, fluid characteristics, pressure requirements and connection arrangement before installation.
- Install the meter with the recommended straight pipe arrangement upstream and downstream. Use a suitable strainer where debris may be present.
- Connect the pickup to the compatible preamplifier, totalizer or flow computer.
- Enter the applicable meter K-factor into the connected instrumentation according to the meter documentation.
- Fill the line gradually and verify the flow reading at normal operating conditions.
Frequently Asked Questions
What flow range does the Barton 7102 turbine flow meter cover?
The Barton 7102 covers 24–240 US GPM in a 2-inch meter size.
How accurate is the Barton 7102?
Rated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.
Can the Barton 7102 measure reverse flow?
Yes. The symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.
What output does the Barton 7102 provide?
The pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.
What is the Barton 7102 used for?
The listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, product transfer, loading operations, chemical injection and allocation metering.
What is the difference between the Barton 7102 and 7202?
Both models are 2-inch turbine meters covering 24–240 US GPM. The Barton 7102 has a listed 1-inch end connection, while the Barton 7202 has a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation connection requirements.
What information should I provide when requesting a quote?
Provide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range and pressure requirements. This helps confirm the appropriate configuration and availability.
How much does the Barton 7102 cost?
Pricing is quote-based. Contact General Tech Services LLC for current pricing and lead-time information.
Request a Quote Today
For Barton 7102 pricing, availability or technical requirements, contact General Tech Services LLC, Saudi Office, Dammam.
Call +966 569 289 544 | www.generaltechshop.sa