ASCO P494A0022100A00, Magneto Resistive PNP Pneumatic Position Detector, IP67, IP69K, 10 to 30V dc, NO Operation, 494, with
Part No. P494A0022100A00
The ASCO P494A0022100A00 is a Series 494 magneto-resistive (MR) PNP position detector for cylinders with T-profile grooves. It provides a normally open output on a 10-30 V DC supply and is sealed to IP67 and IP69K for demanding wash-down environments. Genuine ASCO detector, supplied in the UAE by General Tech Services LLC. Pricing is quote-based. Request a quote in under a minute - call +971 6 543 6933.
The ASCO P494A0022100A00 uses magneto-resistive sensing to detect the permanent magnet on a cylinder piston through the barrel wall without physical contact. The non-contact design has no mechanical switching contacts, making it suitable for high-cycle pneumatic machinery where contact wear can be a concern.
The detector provides a PNP, normally open output on a 10-30 V DC supply, making it suitable for standard sourcing PLC inputs. The electrical connection is determined by the connection variant associated with this part code and should be confirmed against the order before dispatch.
With IP67 and IP69K protection, the detector is designed for applications exposed to high-pressure, high-temperature wash-down and temporary immersion. It is suitable for packaging, bottling, food processing and other industrial machinery requiring reliable cylinder position detection.
The Series 494 detector is designed for cylinders and actuators with T-profile grooves. Before ordering, confirm the cylinder groove profile, PLC or relay input type, supply voltage and required electrical connection. Send the cylinder series and bore to General Tech Services LLC so compatibility can be confirmed before dispatch.
Ready to order the ASCO P494A0022100A00? Speak to our team. Call +971 6 543 6933
Key Benefits
-
Magneto-resistive sensing with no mechanical switching contacts
-
PNP normally open output for standard sourcing PLC inputs
-
10-30 V DC supply range
-
IP67 and IP69K protection for demanding wash-down environments
-
Designed for ASCO cylinders with T-profile grooves
-
Connection variant confirmed against the order
-
Non-contact detection of the cylinder piston magnet
-
Suitable for high-cycle pneumatic machinery
-
Genuine ASCO detector supplied by General Tech Services LLC in the UAE
Who This Product Is Best For
-
Packaging, bottling and food-processing lines exposed to regular wash-down
-
PLC-controlled machines requiring reliable cylinder end-position signals
-
Maintenance teams standardising cylinder sensors across a plant
-
High-cycle pneumatic machinery where mechanical contact wear is a concern
How to Install & Use It
-
Confirm the cylinder groove type, supply voltage, output requirements and connection variant against the controller before installation.
-
Slide the detector into the cylinder's T-profile groove or use the appropriate mounting kit where required.
-
Connect the detector according to the specified connection configuration and wire it to the applicable PLC or relay input.
-
Move the cylinder to the required end position and adjust the detector until the LED switches reliably.
-
Lock the detector in position and verify reliable switching through the complete cylinder stroke.
Frequently Asked Questions
What is the ASCO P494A0022100A00?
It is a Series 494 magneto-resistive PNP position detector with a normally open output, 10-30 V DC supply range and IP67/IP69K protection.
How does the P494A0022100A00 detect the piston?
The detector senses the permanent magnet on the cylinder piston through the non-magnetic barrel without physical contact.
Will the P494A0022100A00 survive wash-down?
It has IP67 and IP69K protection. IP67 provides protection against temporary immersion, while IP69K is designed for high-pressure, high-temperature cleaning conditions.
Is the P494A0022100A00 compatible with my PLC?
It provides a PNP normally open output and operates on 10-30 V DC, which suits standard sourcing PLC inputs. Confirm the PLC input requirements before installation.
How many detectors does one cylinder need?
The number depends on the machine's control requirements. Two detectors are commonly used for retracted and extended positions, while some machines may use an additional detector for an intermediate position.
How do I choose the P494A0022100A00 or another Series 494 detector?
Choose the detector based on the cylinder groove profile, output type, supply voltage and electrical connection. Send your cylinder details and detector part number to General Tech Services LLC for compatibility confirmation.
How do I confirm the connection configuration?
The connection is determined by the specific code variant. Confirm the complete part number and machine connection requirements with General Tech Services LLC before ordering.
How do I get a price and lead time?
Pricing is quote-based. Call General Tech Services LLC on +971 6 543 6933 or submit the Request a Quote form.
Is this a genuine ASCO detector?
General Tech Services supplies original ASCO detectors in the UAE with technical support.
For pricing or to place an order, contact General Tech Services LLC. Call +971 6 543 6933.