Barton 7103 3 inch liquid turbine flow meter product photo

Barton 7103 Flanged RF meter, meter Size :3 inch,End Connection Size :1 inch,Flow Rate :70-700 US GPM

Part Number : TFM/7103/3 inch

Genuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.

Part No. 7103

Product Overview

The Barton 7103 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 70–700 US GPM flow range. The 3-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses each passing blade and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.

The Barton 7103 provides ±0.25% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%.

Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 1-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections. The supplied product listing identifies this 7103 configuration as flanged.

The listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.

Before ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.

Key Benefits

  • Measures 70–700 US GPM in a 3-inch meter size
  • ±0.25% of reading linearity over the stated flow range
  • ±0.15% linearity over limited flow ranges
  • ±0.02% repeatability
  • Bidirectional design for reverse-flow applications
  • Sine-wave pickup output for compatible flow electronics
  • Compatible with digital readouts, totalizers and flow computers
  • Suitable for hydrocarbon measurement applications
  • Supplied configuration identified as flanged

Who This Product Is Best For

The Barton 7103 is suitable for:

  • Oil and gas metering and allocation applications
  • Loading, transfer and terminal operations
  • Process and instrumentation engineering
  • Chemical injection systems
  • Maintenance teams replacing a compatible Barton turbine meter
  • Industrial buyers requiring genuine Barton instrumentation in Saudi Arabia

How to Install & Use It

  1. Confirm that the required normal and maximum flow rates fall within the 70–700 US GPM range and that the meter size and fluid are suitable.
  2. Verify the required end-connection arrangement, pressure rating and installation dimensions before installation.
  3. Install the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.
  4. Connect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.
  5. Enter the applicable meter K-factor into the connected flow electronics according to the meter documentation.
  6. Fill the line gradually and verify the flow indication at normal operating conditions.

Frequently Asked Questions

What flow range does the Barton 7103 cover?

The Barton 7103 covers 70–700 US GPM in a 3-inch meter size.

How accurate is the Barton 7103?

Linearity is ±0.25% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.

Can the Barton 7103 measure reverse flow?

Yes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.

What type of output does the meter provide?

The pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.

What is the Barton 7103 used for?

The listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.

What is the difference between the Barton 7103 and 7203?

Both are 3-inch turbine meters, but the supplied specifications differ in flow range and listed end connection. The Barton 7103 covers 70–700 US GPM with a listed 1-inch end connection, while the Barton 7203 covers 58–580 US GPM with a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.

What information should I provide when requesting a quote?

Provide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.

How much does the Barton 7103 cost?

Pricing is quote-based. Call +966 569 289 544 for current pricing and lead-time information.

Request a Quote Today

For pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.

Call +966 569 289 544 | www.generaltechshop.sa

Availability: in stock
For pricing, please contact our experts.