Vaisala MGP262 | CH4 and CO2 Multigas Probe for Biogas | 0…5 % CH4, ±0.15 % accuracy, Ex certified
The Vaisala CARBOCAP MGP262 continuously measures methane and carbon dioxide in the offgas of biogas upgrading units. It is a compact, self-contained unit certified for Ex environments. It needs no consumables or sampling and helps minimise methane slip.
Key features
- Measurement range 0…5 % CH4
- Accuracy ±0.15 %
- In-situ measurement, no sampling required
- No consumables
- Ex certified, compact self-contained unit
- Continuous, always-on measurement
- Specifications
- Downloads
| Part Number | MGP262 |
| Brand | Vaisala |
| Series | MGP260 |
| Methane range | 0…5 % CH4 |
| Methane accuracy | ±0.15 % |
| Measured parameters | Methane (CH4) and carbon dioxide (CO2) |
| Certification | Ex certified |
| Application | Offgas from biogas upgrading units |
Related Products
Vaisala MMT143 | Moisture and Temperature Transmitter for Oil | Water activity (aw), IP66 stainless steel, RS-485 Modbus
Vaisala MMT143 | Moisture and Temperature Transmitter for Oil | Water activity (aw), IP66 stainless steel, RS-485 Modbus
Vaisala Optimus OPT100 | Dissolved Gas Analysis (DGA) Monitor | Multi-gas DGA, Total gas pressure method, IP66
Vaisala Optimus OPT100 | Dissolved Gas Analysis (DGA) Monitor | Multi-gas DGA, Total gas pressure method, IP66
Vaisala MHT410 | Moisture, Hydrogen and Temperature Transmitter | Hydrogen and moisture, IP66, DNP3.0 and Modbus RTU
Vaisala MHT410 | Moisture, Hydrogen and Temperature Transmitter | Hydrogen and moisture, IP66, DNP3.0 and Modbus RTU
Vaisala MMT310 | Moisture and Temperature Meter for Oil | Water activity in oil, HUMICAP sensor, Ball valve install
Vaisala MMT310 | Moisture and Temperature Meter for Oil | Water activity in oil, HUMICAP sensor, Ball valve install
Vaisala Indigo202 | Indigo200 Series Transmitter, RS-485 Modbus RTU, Display | RS-485 Modbus RTU, Built-in display, Probe host device
Vaisala Indigo202 | Indigo200 Series Transmitter, RS-485 Modbus RTU, Display | RS-485 Modbus RTU, Built-in display, Probe host device
Vaisala Indigo201 | Indigo200 Series Transmitter, 3 Analog Outputs | 3 analog outputs (mA/V), Probe host device, USB config
Vaisala Indigo201 | Indigo200 Series Transmitter, 3 Analog Outputs | 3 analog outputs (mA/V), Probe host device, USB config
Vaisala MGP241 | Multigas CO2 Instrument for CCUS | 0…100 vol-% CO2, 0…25 vol-% H2O, IP65
Vaisala MGP241 | Multigas CO2 Instrument for CCUS | 0…100 vol-% CO2, 0…25 vol-% H2O, IP65
Vaisala MGP261 | CH4, CO2 and Humidity Multigas Probe for Biogas | CH4, CO2 and humidity, Ex certified, In-situ biogas measurement
Vaisala MGP261 | CH4, CO2 and Humidity Multigas Probe for Biogas | CH4, CO2 and humidity, Ex certified, In-situ biogas measurement