Client Protection
Dedicated Support
Genuine Products
Fluidwell F090 | Intrinsically Safe Multi-Purpose Indicator | input loop powered with very large digits, ambient -40°C to +70°C
The F090-A-PL is an economical loop powered, multi-purpose indicator with large 26mm (1”) high digits. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers. Typical use: Applications where a local general / multi-purpose display is required without monitoring function, linearization or signal re-transmitting.
Key features
- Displays the actual value, measuring unit and loop current.
- Very large 26mm (1") high digits.
- Selectable on-screen time units for flow rate: /sec, /min, /hour, /day or no unit.
- Number of digits for actual value: 5½.
- Piegraph indication: ten segments.
- LED backlight with adjustable intensity.
- Intrinsically safe according ATEX, IECEx and CSA C-US.
- Specifications
- Features
- Downloads
| Part Number | F090 |
| Brand | Fluidwell |
| Product Type | Multi-Purpose Indicator |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Supply - Power Supply | 4 – 20mA, input Loop-powered. |
| Signal Inputs - Multi Purpose Inputs | 4 – 20mA input loop-powered. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T200 100 °C Da; CSA: I.S. Class I/II/III, Div 1, Grp A...G, T4 Class I, Zone 0, AEx ia IIC T4 Ga Note: Extended aluminum enclosures not available with CSA/FM approval. |
- shows the loop current, measurement unit, and actual value.
- Huge digits, measuring 26 mm (1") in height.
- %, PPM, meter, m, cm, mm, ft, sqft, ML, L, NL, M³, nM³, GAL, USGAL, IGAL, bbl, CUFT, mg, g, kg, ton, lb, psi, psig, mbar, bar, barg, °C, °F, K, P, RPM, K, KPA, or no unit (others upon request) are among the selectable on-screen engineering units.
- Options for flow rate time units on the screen include /sec, /min, /hour, /day, or none at all.
- Five and a half is the actual value in digits.
- Ten segments indicate the piegraph.
- Backlight made of LEDs with intensity control.
- In accordance with ATEX, IECEx, FM, and CSA C-US, intrinsic safety.
- Enclosures made of GRP, aluminum, or premium stainless steel.
- automatic EEPROM memory backup of configurations.
- Simple setup with readable alphanumeric text.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell D053 | DIN Panel Mount Pressure Monitor | with one high / low alarm output, ambient -40°C to +70°C
Fluidwell D053 | DIN Panel Mount Pressure Monitor | with one high / low alarm output, ambient -40°C to +70°C
Fluidwell F190P | Intrinsically Safe Multi-Purpose Monitor (pressure version) | with alarm outputs and configurable hysteresis, ambient -40°C to +70°C
Fluidwell F190P | Intrinsically Safe Multi-Purpose Monitor (pressure version) | with alarm outputs and configurable hysteresis, ambient -40°C to +70°C
Fluidwell F053 | Intrinsically Safe Pressure Monitor | with one high / low alarm output, ambient -40°C to +70°C
Fluidwell F053 | Intrinsically Safe Pressure Monitor | with one high / low alarm output, ambient -40°C to +70°C
Fluidwell E490P | Explosion proof Multi-Purpose Indicator (pressure version) | Loop Powered, for universal applications, ambient -40°C to +70°C
Fluidwell E490P | Explosion proof Multi-Purpose Indicator (pressure version) | Loop Powered, for universal applications, ambient -40°C to +70°C
Fluidwell D490P | DIN Panel Mount, Intrinsically Safe Multi-Purpose Indicator (pressure version) | Loop Powered, for universal applications, ambient -30°C to +70°C
Fluidwell D490P | DIN Panel Mount, Intrinsically Safe Multi-Purpose Indicator (pressure version) | Loop Powered, for universal applications, ambient -30°C to +70°C
Fluidwell D090P | DIN Panel Mount Multi-Purpose Indicator (pressure version) | input loop powered with very large digits, ambient -40°C to +70°C
Fluidwell D090P | DIN Panel Mount Multi-Purpose Indicator (pressure version) | input loop powered with very large digits, ambient -40°C to +70°C
Fluidwell D050 | DIN Panel Mount Pressure Indicator | with very large digits, ambient -40°C to +70°C
Fluidwell D050 | DIN Panel Mount Pressure Indicator | with very large digits, ambient -40°C to +70°C
Fluidwell F050 | Intrinsically Safe Pressure Indicator | with very large digits, ambient -40°C to +70°C
Fluidwell F050 | Intrinsically Safe Pressure Indicator | with very large digits, ambient -40°C to +70°C