Fluidwell E018 | Explosion proof Flow rate Monitor / Totalizer | with linearization, high / low alarms, analog and pulse signal outputs and HART Communication, ambient -40°C to +70°C
The E018 flow computer is one of the top models in our range of explosion proof flow computers. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems. In addition to the average K-Factor, 16 linearization points can be entered. Typical use: Flow measurement with mechanical flowmeters, where re-transmission of the totalizer, monitoring of the flow rate and HART communication is required.
Key features
- Explosion proof according ATEX, IECEx and CSA C-US.
- Aluminum or high grade stainless steel Ex d enclosure.
- Easy installation with the spacious chamber and plug & play connectors.
- Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
- High and low flow rate alarm monitoring.
- 15 point linearization of the flow curve - with interpolation.
- 7 digit flow rate / total and 11 digit accumulated total.
- Specifications
- Features
- Downloads
| Part Number | E018 |
| Brand | Fluidwell |
| Product Type | Flow rate Monitor / Totalizer |
| Enclosure / Area | Explosion proof |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA. Output loop-powered.; 9 – 27V DC. |
| Supply - Sensor Supply | 3, 8.2, 12, 24V DC. |
| Signal Inputs - Status Inputs | Remote control: external input for clearing total or to disable manual clearing by the keypad. |
| Signal Outputs - Pulse Outputs | Function: 4 Scaled pulse outputs according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.; Type: Four passive NPN transistors and two isolated electro-mechanical relays. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting the linearized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).; Type: One galvanically isolated, loop powered 4 – 20mA output. |
| Communication | Function: Reading display information, clear total and all settings can easily be read and modified through the HART communication link with al registered "DD enabled host" systems. Protocol: HART, Revision 7.0. Device specific DD can be downloaded at the dropdown downloads above . |
| Signal Outputs - Alarm Outputs | Function: Configurable alarm outputs for low, high or both flow rate alarms.; Type: Four passive NPN transistors and two isolated electro-mechanical relays. |
| Hazardous Area - Explosion Proof | ATEX: Gas: II 2 G Ex db IIC T6 Gb. Dust: II 2 D Ex tb IIIC T85 °C Db.; IECEX: Gas: Ex db IIC T6 Gb. Dust: Ex tb IIIC T85 °C Db.; CSA C-US: XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D. DIP (Dust-Ignition-proof): Class II, Div. 1, Groups E, F, & G T85 °C; Class III. Gas: Class I, Zone 1, AEx db IIC T6 Gb. Dust: Zone 21, AEx tb IIIC T85 °C Db. |
- In accordance with ATEX, IECEx, FM, and CSA C-US, explosion proof.
- Ex terior enclosure made of premium stainless steel or aluminum.
- Plug and play connectors and a roomy chamber make installation simple.
- Installing a direct flowmeter mounting nozzle with a 1" NPT thread is simple and saves money.
- A flow rate-indicating speedometer, measurement units, total, accumulated total, alarm values, and alarm messages are all displayed on the display, providing important information at a glance.
- Monitoring of alarms for high and low flow rates.
- The flow curve was linearized to 15 points using interpolation.
- 11-digit cumulative total and 7-digit flow rate/total.
- Clear backlight with LED flashing in the event of an alert.
- Run totals and settings are automatically backed up.
Other models in this series
Click a row to open that product.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Nuflo MC II Analyser | Flow Indicator
Nuflo MC II Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Nuflo MC III Analyser | Flow Indicator
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-3/4 | Polycarbonate Sight Flow Indicator | 3-35 GPM, 3/4" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT
Dwyer SFI-801-1/2-A711 | Polycarbonate Sight Flow Indicator with A-711 Sensor | 2-20 GPM, 1/2" female NPT