Dwyer RSMC-B-004-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 1 inH₂O, ± 0.5 %
The Dwyer RSMC-B-004-SS is a StabiliSENSE™ critical room status monitor: critical room status monitor, range 0-1.0" w.c., ± 0.5% accuracy with SS bezel.
The Dwyer Series RSMC StabiliSENSE™ Critical Room Status Monitor is designed for critical low differential pressure applications requiring stringent monitoring and alarming. The series supports positive or negative pressure configurations in clean rooms, hospital isolation rooms, school nurses offices, laboratories, and vivariums. The Series RSMC utilizes a capacitance cell pressure sensor to measure air service with selectable ranges including 0 to 0.25 in w.c., 0 to 0.5 in w.c., 0 to 1 in w.c., -0.25 to 0.25 in w.c., -0.5 to 0.5 in w.c., and -1.00 to 1.00 in w.c.
- Accuracy: ± 0.5 %
- Accuracy Detail: ± 0.5% RSS (includes non-linearity: ± 0.49% BFSL, hysteresis: ± 0.05% and non-repeatability: ± 0.05%).
- Alarm: 69.1 dB 10 cm from display
- Data Interface: BACnet MS/TP, Modbus RTU
- Display Note: 4.3" (10.9 cm) color TFT LCD, dimmable; 480 x 272 Resolution.
- Display Type: TFT LCD
- Specifications
- Features
- Downloads
| Part Number | RSMC-B-004-SS |
| Brand | Dwyer |
| Series | RSMC |
| Accuracy | ± 0.5 % |
| Electrical Connection | Screw Terminal |
| Supply Voltage | 24 Vac/Vdc |
| Weight | 1.05 lb |
| Accuracy Detail | ± 0.5% RSS (includes non-linearity: ± 0.49% BFSL, hysteresis: ± 0.05% and non-repeatability: ± 0.05%). |
| Alarm | 69.1 dB 10 cm from display |
| Data Interface | BACnet MS/TP, Modbus RTU |
| Display Note | 4.3" (10.9 cm) color TFT LCD, dimmable; 480 x 272 Resolution. |
| Display Type | TFT LCD |
| Height | 5.375 in |
| Input Control Signal | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc |
| Input Control Signal Note | Two (2) user-selectable 4-20 mA, 0-5 VDC, or 0-10 VDC; USB type C used for cloning programming; One (1) digital input for door status. |
| Length | 1.7188 in |
| Materials | Stainless Steel |
| Measurement Pressure, Max | 1 inH₂O |
| Measurement Pressure, Min | 0 inH₂O |
| Measurement Type | Current, Voltage, Digital |
| Operating Temperature, Max | 122 °F |
| Operating Temperature, Min | 32 °F |
| Output Detail | Current: 4 to 20 mA, Voltage: 0 to 10 Vdc, Digital: 5 A @ 30 Vdc;One (1) digital output (DO) rated 5 A @ 30 VDC; One (1) 4-20 mA or 0-10 V (user selectable) corresponding to internal pressure or retransmission of any input. |
| Output Signal | Current, Voltage, Digital |
| Power Consumption | 3.6 W |
| Pressure Limits | up to 1.5 psi |
| Process Connection Note | Barbed, fits 1/8˝ and 3/16˝ (3 mm and 5 mm) ID rubber or vinyl tubing. |
| Process Connection Size | 1/8 in, 3/16 in |
| Process Connection Type | Barbed Fitting |
| Sensor Type | Capacitive pressure sensor |
| Supply Power Type | AC/DC |
| Width | 9.2344 in |
| Zero Setting Adjustable Range | Adjustable via Touchscreen |
| Country of Origin | Spain |
- Accuracy: ± 0.5 %
- Accuracy Detail: ± 0.5% RSS (includes non-linearity: ± 0.49% BFSL, hysteresis: ± 0.05% and non-repeatability: ± 0.05%).
- Alarm: 69.1 dB 10 cm from display
- Data Interface: BACnet MS/TP, Modbus RTU
- Display Note: 4.3" (10.9 cm) color TFT LCD, dimmable; 480 x 272 Resolution.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer RSMC-B-014-SS | StabiliSENSE™ Critical Room Status Monitor | -0.5 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-014-SS | StabiliSENSE™ Critical Room Status Monitor | -0.5 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-003-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-003-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.5 inH₂O, ± 0.5 %
Dwyer RSMC-B-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-002-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-B-002-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-A-004-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-A-004-SS | StabiliSENSE™ Critical Room Status Monitor | 0 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-B-015 | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-B-015 | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSMC-A-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-A-015-SS | StabiliSENSE™ Critical Room Status Monitor | -1 to 1 inH₂O, ± 0.25 %
Dwyer RSMC-B-013-SS | StabiliSENSE™ Critical Room Status Monitor | -0.25 to 0.25 inH₂O, ± 0.5 %
Dwyer RSMC-B-013-SS | StabiliSENSE™ Critical Room Status Monitor | -0.25 to 0.25 inH₂O, ± 0.5 %