Client Protection
Dedicated Support
Dwyer RSM-1-B | Room Pressure Monitor | -0.05 to 0.05 inH₂O, ± 0.5 %
The Dwyer RSM-1-B is a room pressure monitor: room status monitor, range ± 0.05" w.c., excitation 120 VAC.
The Dwyer Series RSM Room Status Monitor is designed for critical low differential pressure applications requiring stringent monitoring and alarming. The series supports positive or negative pressure monitoring in protected environments, including hospital isolation rooms configured per CDC guidelines. The Series RSM measures differential pressure with a resolution of 0.001 in w.c. Accuracy is specified as ±0.5% FS, with an optional accuracy class of ±0.25% FS available.
- Accuracy: ± 0.5 %
- Accuracy Detail: ± 0.5% FS
- Data Interface: BACnet MS/TP ASC Optional
- Electrical Connection: Screw Terminal
- Enclosure Ratings: IP20, NEMA Type 1
- Enclosure Ratings Note: NEMA 1 (IP20) rated for indoor applications
- Specifications
- Features
- Downloads
| Part Number | RSM-1-B |
| Brand | Dwyer |
| Series | RSM |
| Accuracy | ± 0.5 % |
| Mounting | Mount to standard double gang metal electrical box using 4x4" plaster ring adaptor |
| Electrical Connection | Screw Terminal |
| Supply Voltage | 85 to 265 Vac |
| Weight | 1.5 lb |
| Accuracy Detail | ± 0.5% FS |
| Data Interface | BACnet MS/TP ASC Optional |
| Enclosure Ratings | IP20, NEMA Type 1 |
| Enclosure Ratings Note | NEMA 1 (IP20) rated for indoor applications |
| Height | 8 in |
| Length | 1.8 in |
| Loop Resistance | 0 to 510 Ω |
| Materials | Fire Retardant Plastic |
| Measurement Pressure, Max | 0.05 inH₂O |
| Measurement Pressure, Min | -0.05 inH₂O |
| Number of Wires | 2, 3 |
| Operating Temperature, Max | 120 °F |
| Operating Temperature, Min | 32 °F |
| Output Detail | 2-Wire: 4 to 20 mA; 3-Wire: 0 to 5 Vdc, 0 to 10 Vdc;Selectable 4-20 mA (2-wire), 0-5 VDC (3-wire), or 0-10 VDC (3-wire) |
| Output Signal | Current, Voltage |
| Power Consumption | 5 W |
| Pressure Limits | -15 inH2O to 15 inH2O |
| Process Connection Note | Barbed Fittings for 3/16˝ ID Tubing. |
| Process Connection Size | 3/16 in |
| Process Connection Type | Barbed Fitting |
| Relative Humidity | 5 to 95% RH (non-condensing) |
| Supply Power Note | Order code B (120 VAC): 85-265 VAC, 50 to 60 Hz; Main supply voltage fluctuations up to 10%. |
| Supply Power Type | AC |
| Switch Type | SPST |
| Thermal Effects | ± 0.03% FS/°F |
| Width | 5.4 in |
| Country of Origin | United States |
- Accuracy: ± 0.5 %
- Accuracy Detail: ± 0.5% FS
- Data Interface: BACnet MS/TP ASC Optional
- Electrical Connection: Screw Terminal
- Enclosure Ratings: IP20, NEMA Type 1
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-014-SS | Room Status Monitor | -0.5 to 0.5 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-C-004-SS | Room Status Monitor | 0 to 1 inH₂O, ± 1 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-016-SS | Room Status Monitor | -2 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-005-SS | Room Status Monitor | 0 to 2 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %
Dwyer RSME-B-015-SS | Room Status Monitor | -1 to 1 inH₂O, ± 0.5 %