Dwyer MARK II 40-250PA-AV | Molded Plastic Manometer | 0-260 Pa & 0-21 m/s, Red Fluid
Dwyer MARK II 40-250PA-AV is a metric-scaled molded plastic manometer reading 0-260 Pa and 0-21 m/s, using red gage fluid (0.826 sp. gr.). Use it with a Pitot tube, sold separately.
- Supplied with range 0-260 Pa & 0-21 m/s, red gage fluid (0.826 sp. gr.)
- Measures pressure and differential pressure above or below atmospheric; ±3% FS accuracy
- Built-in overpressure safety traps and quick shut-off connections; RoHS II compliant
- Pitot tube must be ordered separately; rated to 10 psi inclined-vertical, 15 psi inclined
- Specifications
- Features
- Downloads
| Part Number | MARK II 40-250PA-AV |
| Brand | Dwyer |
| Series | Mark II Molded Plastic Manometers |
| Range | 0-260 Pa & 0-21 m/s |
| Accuracy | ±3% FS |
| Maximum Pressure | Inclined/vertical: 10 psi; inclined: 15 psi |
| Approvals | RoHS II (2011/65/EU) |
| Pitot Tube | Required, sold separately |
| Gage Fluid | Red |
| Specific Gravity | 0.826 |
- Almost unbreakable thick white styrene-acrylonitrile housing.
- An overflow tank (Model 25) or float-operated overflow traps (Model 40) can handle moderate overpressures.
- Able can be fixed in any upright position.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer 3000MRS-100MM | Photohelic® Switch/Gage | 0 inH₂O to 100 mmHg, ± 2 %
Dwyer 3000MRS-100MM | Photohelic® Switch/Gage | 0 inH₂O to 100 mmHg, ± 2 %
Dwyer 3000MRS-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-250PA | Photohelic® Switch/Gage | 0 inH₂O to 250 Pa, ± 2 %
Dwyer 3000MRS-250PA | Photohelic® Switch/Gage | 0 inH₂O to 250 Pa, ± 2 %
Dwyer 3000MRS-3KPA | Photohelic® Switch/Gage | 0 inH₂O to 3 kPa, ± 2 %
Dwyer 3000MRS-3KPA | Photohelic® Switch/Gage | 0 inH₂O to 3 kPa, ± 2 %
Dwyer 3000MRS-10MM | Photohelic® Switch/Gage | 0 inH₂O to 10 mmHg, ± 3 %
Dwyer 3000MRS-10MM | Photohelic® Switch/Gage | 0 inH₂O to 10 mmHg, ± 3 %
Dwyer 3000MRS-125PA | Photohelic® Switch/Gage | 0 inH₂O to 125 Pa, ± 3 %
Dwyer 3000MRS-125PA | Photohelic® Switch/Gage | 0 inH₂O to 125 Pa, ± 3 %
Dwyer 3000MR-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MR-500PA | Photohelic® Switch/Gage | 0 inH₂O to 500 Pa, ± 2 %
Dwyer 3000MRS-25MM | Photohelic® Switch/Gage | 0 inH₂O to 25 mmHg, ± 2 %
Dwyer 3000MRS-25MM | Photohelic® Switch/Gage | 0 inH₂O to 25 mmHg, ± 2 %