Part Number : IF2717

Genuine Dwyer instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.

Part No. IF2717

Product Overview

The Dwyer IF2717 direct reading flowmeter provides direct flow indication from its scale, allowing operators to read flow without converting float readings through correlation charts. It is rated for water flow up to 44 GPM (167 LPM) and air flow up to 180 SCFM (5098 LPM).

The IF2717 is part of Dwyer's Series IF industrial direct reading flowmeters. It features a 2-inch female NPT connection and a listed pressure drop of 30 inches w.c. The meter is designed for applications requiring direct visual flow indication for water or compressed air.

The flow tube is made from borosilicate glass. The float, guide rods, float stops and end fittings are 316 stainless steel, while fluoroelastomer O-rings provide sealing. A detachable 3/16-inch-thick polycarbonate front shield protects the flow tube, and the side panels are 304 stainless steel.

The Dwyer IF2717 provides ±3% of full-scale accuracy, ±0.5% full-scale repeatability and a 10:1 turndown. Maximum operating pressure is 200 psi (13.8 bar), with a 125 psi limit specified for tube sizes 5 and 6. Maximum operating temperature is 200°F (93°C).

The flowmeter is designed for vertical mounting. Typical applications include cooling-water and process-water lines, compressed-air distribution, filtration and treatment skids, and industrial test benches. Before ordering, confirm the required flow range, fluid, operating pressure, temperature and pipe connection size.

General Tech Services supplies genuine Dwyer instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and our team can confirm compatibility, availability and pricing.

Need a higher flow range? The Dwyer IF2718 is a related Series IF direct reading flowmeter rated for up to 60 GPM (227 LPM) of water and 245 SCFM (6938 LPM) of air with a 2-inch NPT connection.

Key Benefits

  • Direct reading up to 44 GPM (167 LPM) of water
  • Air flow rating up to 180 SCFM (5098 LPM)
  • No correlation charts required for direct scale reading
  • ±3% of full-scale accuracy
  • ±0.5% full-scale repeatability
  • 10:1 turndown
  • 316 stainless steel float, guide rods, stops and end fittings
  • Borosilicate glass flow tube
  • Polycarbonate front shield with 304 stainless steel side panels
  • Free Saudi Arabia shipping available

For pricing or lead time, call +966 569 289 544 for a fast quote.

Who This Product Is Best For

  • Process and utility engineers
  • Water-treatment and filtration operators
  • Compressed-air system technicians
  • Cooling-water and process-water operators
  • Maintenance teams replacing a like-for-like Dwyer meter
  • Industrial buyers in Saudi Arabia requiring genuine Dwyer instruments

How to Install & Use It

  1. Confirm that the required flow range, fluid, operating pressure and temperature are compatible with the meter.
  2. Mount the flowmeter vertically in the line, with flow entering through the bottom inlet.
  3. Connect the meter using the specified 2-inch NPT fittings and suitable thread-sealing practices.
  4. Open the supply gradually and read the flow rate from the float position against the appropriate scale.

Follow the applicable Dwyer installation documentation and site procedures for complete installation requirements.

Frequently Asked Questions

What is the maximum flow of the Dwyer IF2717?

The IF2717 is rated for up to 44 GPM (167 LPM) of water and 180 SCFM (5098 LPM) of air.

How accurate is the Dwyer IF2717?

The rated accuracy is ±3% of full scale, with ±0.5% full-scale repeatability and a 10:1 turndown.

What pressure and temperature can the IF2717 handle?

The supplied Series IF data lists a maximum operating pressure of 200 psi (13.8 bar), with 125 psi specified for tube sizes 5 and 6. Maximum temperature is 200°F (93°C).

What is the connection size?

The Dwyer IF2717 has a 2-inch female NPT connection.

Can the Dwyer IF2717 measure air?

Yes. The IF2717 has a listed maximum air flow of 180 SCFM (5098 LPM).

What is the pressure drop of the IF2717?

The supplied specification lists a pressure drop of 30 inches w.c.

What is the difference between the Dwyer IF2717 and IF2718?

Both are Series IF direct reading flowmeters with a 2-inch NPT connection and ratings for both water and air. The IF2717 is rated for up to 44 GPM of water and 180 SCFM of air, while the IF2718 is rated for up to 60 GPM of water and 245 SCFM of air. Selection should be based on the required flow range and fluid.

What information should I provide when requesting a quote?

Provide the model number, quantity and delivery city, together with application details such as fluid, required flow range, pressure and temperature. This helps confirm the appropriate configuration.

How much does the Dwyer IF2717 cost?

Pricing is quote-based. Call +966 569 289 544 for current pricing and lead time.

Request a Quote Today

For pricing, availability or ordering assistance, contact General Tech Services LLC.

Call +966 569 289 544 | www.generaltechshop.sa

Availability: in stock
Free Saudi Arabia shipping available
For pricing, please contact our experts.