Client Protection
Dedicated Support
Desoutter PST 5 Nm – 13 | Digital Pulse Static Transducer | 0.5-5 Nm, 1/2 in Sq Input
Rated 0.5 Nm (0.4 ft.lbf) up to 5 Nm (3.7 ft.lbf), the PST 5 Nm – 13 static transducer from Desoutter (part 6159352210) takes a 1/2 in square input drive and is specified at ±0.35% FSD. The PST 5 Nm – 13 pairs with a Delta 6 or 7D to test wrenches, pulse tools and electric nutrunners.
Key features
- Smart memory chip in the PST 5 Nm – 13 for automatic recognition, avoiding setting errors
- Overload torque of 6.25 Nm (4.6 ft.lbf) on the PST 5 Nm – 13
- Digital communication from the PST 5 Nm – 13 for fast data transfer without external noise
- Small footprint; the PST 5 Nm – 13 can be fixed to the top or bottom of a table
- Works with the Desoutter DJS joint simulator range to reproduce test conditions on the PST 5 Nm – 13
- Specifications
- Downloads
| Part Number | 6159352210 |
| Model | PST 5 Nm – 13 |
| Brand | Desoutter |
| Measurand | Torque |
| Min Torque capacity | 0.5 Nm (0.4 ft.lbf) |
| Max Torque capacity | 5 Nm (3.7 ft.lbf) |
| Overload torque | 6.25 Nm (4.6 ft.lbf) |
| Input drive size | 1/2 |
| Input drive type | Sq |
| Accuracy | ± 0.35% FSD (Full Scale Deviation) |
| Signal Type | Digital |
| Transducer Type | Static |
| Weight | 1.4 kg (3.09 lb) |
Related Products
SAUTER DC 100-Y1 | Static Torque Sensor | 0.5% F.S. Error, 1.9 mV/V
SAUTER DC 100-Y1 | Static Torque Sensor | 0.5% F.S. Error, 1.9 mV/V
SAUTER DC 10-Y2 | Static Torque Sensor DC 10-Y2 | 0.5% Combined Error, IP65
SAUTER DC 10-Y2 | Static Torque Sensor DC 10-Y2 | 0.5% Combined Error, IP65
SAUTER DC 10-Y1 | Static Torque Sensor DC 10-Y1 | 0.5% Combined Error, 1.2 mV/V
SAUTER DC 10-Y1 | Static Torque Sensor DC 10-Y1 | 0.5% Combined Error, 1.2 mV/V
SAUTER DC 200-Y1 | Static Torque Sensor DC 200-Y1 | Alloy Steel, 0.5 % Combined Error
SAUTER DC 200-Y1 | Static Torque Sensor DC 200-Y1 | Alloy Steel, 0.5 % Combined Error
SAUTER DC 20-Y1 | Static Torque Sensor | 0.5% Combined Error, 1.3 mV/V
SAUTER DC 20-Y1 | Static Torque Sensor | 0.5% Combined Error, 1.3 mV/V
SAUTER DC 20-Y2 | Static Torque Sensor | 0.5% Combined Error, IP65
SAUTER DC 20-Y2 | Static Torque Sensor | 0.5% Combined Error, IP65
SAUTER DC 200M-Y2 | Static Torque Sensor DC 200M-Y2 | Alloy Steel, 0.5% F.S., IP65
SAUTER DC 200M-Y2 | Static Torque Sensor DC 200M-Y2 | Alloy Steel, 0.5% F.S., IP65
SAUTER DC 5-Y1 | Static Torque Sensor | Alloy Steel, 1.5 mV/V
SAUTER DC 5-Y1 | Static Torque Sensor | Alloy Steel, 1.5 mV/V