Brannan 10/412/0 | BS 718 M100 SP Density Hydrometer | 1.80–1.90 g/ml, 250 mm
Covering 1.80–1.90 g/ml, the 10/412/0 belongs to the Brannan M100 SP family of density hydrometers built to BS 718:1991. Between 1.80 and 1.90 g/ml the scale is marked in 0.002 g/ml increments; the 10/412/0 is 250 mm long and adjusted at 20 °C. As an SP sub-series instrument, the 10/412/0 is made to a higher accuracy than the standard M100 series, with a stated accuracy of 0.002 g/ml.
Key features
- Range 1.80 to 1.90 g/ml
- 0.002 g/ml divisions over a 0.100 g/ml span
- 250 mm overall length, 18–20 mm bulb diameter
- Adjusted at 20 °C
- Accuracy 0.002 g/ml, higher than the standard M100 series
- Made in the UK, supplied in a resealable protective tube
Brannan can supply the 10/412/0 with UKAS certification, a certificate traceable to a recognised national standard, or a statement of conformity.
- Specifications
- Downloads
| Part Number | 10/412/0 |
| Brand | Brannan |
| Series | M100 SP |
| Standard | BS 718:1991 (generally aligned with ISO 387 and ISO 649) |
| Density Range | 1.80–1.90 g/ml |
| Range Span | 0.100 g/ml |
| Divisions | 0.002 g/ml |
| Accuracy | 0.002 g/ml |
| Overall Length | 250 mm |
| Bulb Diameter | 18–20 mm |
| Approx. Weight | 42 g (incl. 14 g protective tube) |
| Adjustment Temperature | 20 °C |
| Material | Soda glass, steel shot ballast, synthetic wax resin |
| Country of Manufacture | UK |
Related Products
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension