{"title":"Flowmeters","description":null,"products":[{"product_id":"barton-7183-rf-meter-meter-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-45-4-us-gpm","title":"Barton 7183 RF meter, meter Size :3\/8 inch,End Connection Size :1 inch,Flow Rate :0.45-4 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7183\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7183 turbine flow meter is a 3\/8-inch Cameron BARTON® Series 7000 liquid turbine meter designed for liquid measurement across a 0.45–4 US GPM flow range. It provides ±1% of reading linearity over the stated flow range, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7183 has a listed 1-inch end connection size and a symmetrical, bidirectional design that supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm that the normal and maximum flow requirements are within the meter's range. Also check the required line size, end-connection style, fluid, pressure rating and compatible electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and our team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeed a different connection configuration? The Barton 7283 is another 3\/8-inch turbine meter covering 0.5–5 US GPM, with a listed 2-inch end connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 0.45–4 US GPM in a 3\/8-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for listed hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing or lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a fast quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the required flow range, line size, fluid and pressure conditions are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream, and use a strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and configure the meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter reading at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Barton installation documentation and site procedures for the complete installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7183 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7183 covers 0.45–4 US GPM in a 3\/8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7183?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7183 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7183 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7183 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7183 and 7283?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3\/8-inch turbine meters, but their listed flow ranges and end connections differ. The 7183 covers 0.45–4 US GPM with a listed 1-inch end connection, while the 7283 covers 0.5–5 US GPM with a listed 2-inch end connection. Selection should be based on the required flow and connection arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid, required flow range and pressure conditions. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7183 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170170867825,"sku":"TFM\/7183\/3\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7183-rf-meter-meter-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-45-4-us-gpm-25381831704689.jpg?v=1761752379"},{"product_id":"barton-7184-rf-meter-meter-size-1-2-inch-end-connection-size-1-inch-flow-rate-0-88-8-2-us-gpm","title":"Barton 7184 RF meter,meter  Size :1\/2 inch,End Connection Size :1 inch,Flow Rate :0.88-8.2 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7184\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7184 turbine flow meter is a 1\/2-inch Cameron BARTON® Series 7000 liquid turbine meter designed for liquid measurement across a 0.88–8.2 US GPM flow range. It provides ±1% of reading linearity over the stated flow range, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7184 has a listed 1-inch end connection size and a symmetrical, bidirectional design that supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm that the normal and maximum flow requirements are within the meter's range. Also check the required line size, end-connection style, fluid, pressure rating and compatible electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and our team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeed a different connection configuration? The Barton 7284 is another 1\/2-inch turbine meter covering 1–10 US GPM, with a listed 2-inch end connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 0.88–8.2 US GPM in a 1\/2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for listed hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing or lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a fast quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the required flow range, line size, fluid and pressure conditions are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream, and use a strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and configure the meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter reading at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Barton installation documentation and site procedures for the complete installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7184 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7184 covers 0.88–8.2 US GPM in a 1\/2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7184?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7184 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7184 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7184 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7184 and 7284?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 1\/2-inch turbine meters, but their listed flow ranges and end connections differ. The 7184 covers 0.88–8.2 US GPM with a listed 1-inch end connection, while the 7284 covers 1–10 US GPM with a listed 2-inch end connection. Selection should be based on the required flow and connection arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid, required flow range and pressure conditions. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7184 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170170900593,"sku":"TFM\/7184\/1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7184-rf-meter-meter-size-1-2-inch-end-connection-size-1-inch-flow-rate-0-88-8-2-us-gpm-25381831966833.jpg?v=1761752378"},{"product_id":"barton-7185-rf-meter-meter-size-5-8-inch-end-connection-size-1-inch-flow-rate-1-6-16-us-gpm","title":"Barton 7185 RF meter, meter Size :5\/8 inch,End Connection Size :1 inch,Flow Rate :1.6-16 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7185\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7185 turbine flow meter is a 5\/8-inch Cameron BARTON® Series 7000 liquid turbine meter designed for liquid measurement across a 1.6–16 US GPM flow range. It provides ±1% of reading linearity over the stated flow range, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7185 has a listed 1-inch end connection size and a symmetrical, bidirectional design that supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm that the normal and maximum flow requirements are within the meter's range. Also check the required line size, end-connection style, fluid, pressure rating and compatible electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and our team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeed a different connection configuration? The Barton 7285 is another 5\/8-inch Series 7000 turbine meter covering 1.6–16 US GPM, with a listed 2-inch end connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 1.6–16 US GPM in a 5\/8-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for listed hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing or lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a fast quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the required flow range, line size, fluid and pressure conditions are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream, and use a strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and configure the meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter reading at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Barton installation documentation and site procedures for the complete installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7185 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7185 covers 1.6–16 US GPM in a 5\/8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7185?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7185 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7185 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7185 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7185 and 7285?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 5\/8-inch turbine meters covering 1.6–16 US GPM. The supplied listings identify a 1-inch end connection for the 7185 and a 2-inch end connection for the 7285. Selection should be based on the required connection and installation arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid, required flow range and pressure conditions. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7185 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170170966129,"sku":"TFM\/7185\/5\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7185-rf-meter-meter-size-5-8-inch-end-connection-size-1-inch-flow-rate-1-6-16-us-gpm-25381832097905.jpg?v=1761752377"},{"product_id":"barton-7186-rf-meter-meter-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-3-23-us-gpm","title":"Barton 7186 RF meter, meter Size :3\/4 inch,End Connection Size :1 inch,Flow Rate :2.3-23 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7186\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7186 turbine flow meter is a 3\/4-inch Cameron BARTON® Series 7000 liquid turbine meter designed for liquid measurement across a 2.3–23 US GPM flow range. It provides ±1% of reading linearity over the stated flow range, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7186 has a listed 1-inch end connection size and a symmetrical, bidirectional design that supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm that the normal and maximum flow requirements are within the meter's range. Also check the required line size, end-connection style, fluid, pressure rating and compatible electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and our team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeed a different connection configuration? The Barton 7286 is another 3\/4-inch Series 7000 turbine meter covering 2.3–23 US GPM, with a listed 2-inch end connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 2.3–23 US GPM in a 3\/4-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for listed hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing or lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a fast quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instruments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm the required flow range, line size, fluid and pressure conditions are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream, and use a strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and configure the meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter reading at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Barton installation documentation and site procedures for the complete installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7186 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7186 covers 2.3–23 US GPM in a 3\/4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7186?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7186 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7186 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7186 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7186 and 7286?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3\/4-inch turbine meters covering 2.3–23 US GPM. The supplied listings identify a 1-inch end connection for the 7186 and a 2-inch end connection for the 7286. Selection should be based on the required connection and installation arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid, required flow range and pressure conditions. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7186 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170170998897,"sku":"TFM\/7186\/3\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7186-rf-meter-meter-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-3-23-us-gpm-25381832196209.jpg?v=1761752377"},{"product_id":"barton-7101-rf-meter-meter-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm","title":"Barton 7101 RF meter, meter Size :1 inch,End Connection Size :1 inch,Flow Rate :5-50 US GPM","description":"\u003cp\u003e\u003cstrong\u003eModel 7101 · 1\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Barton 7101 is a 1\" liquid turbine flow meter from Barton's Model 7100 range, listed for 5-50 US GPM. It suits low-viscosity liquids including hydrocarbons. Genuine Barton stock at General Tech Services LLC, UAE, with free UAE-wide shipping. Request a quote in under a minute - call \u003cstrong\u003e+971 6 5436933\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: 7101\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eContact Number: +971 6 5436933\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMid-size liquid lines in production, process and transfer service need a meter that reads accurately across a wide flow range. The Barton 7101 is a 1\" turbine meter listed for 5-50 US GPM.\u003c\/p\u003e\n\u003cp\u003eA turbine flow meter places a balanced rotor in the liquid stream. Flow turns the rotor at a speed proportional to flow rate, and a pickup coil on the meter body senses each passing blade tip, producing a pulse signal. Counting the pulses gives volume, and their frequency gives flow rate. The rotor is the only moving part.\u003c\/p\u003e\n\u003cp\u003eThe Barton 7101 belongs to Barton's Model 7100 line, which covers 3\/8 to 8 inch meters. Model 7100 meters use wear-resistant tungsten carbide sleeve bearings, which need no lubrication and stand up to demanding service.\u003c\/p\u003e\n\u003cp\u003eBarton's 7000 series uses a symmetrical bidirectional design, so it can measure flow in either direction where capacities are the same both ways.\u003c\/p\u003e\n\u003cp\u003eBarton's published series data gives linearity of ±0.25% of reading over the flow range and repeatability of ±0.02% of reading. For accurate results, install the meter in straight pipe of the same diameter, with at least 10 pipe diameters of straight run upstream. Confirm materials, pressure rating and electronics against the Barton datasheet and your process before ordering.\u003c\/p\u003e\n\u003cp\u003eNeed a different size or model line? Compare the Barton 7186 (3\/4\", 2.3-23 US GPM), Barton 7145 (1-1\/4\", 10-80 US GPM), or Barton 7201 (1\", 5-50 US GPM).\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1\" meter listed for 5-50 US GPM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor is the only moving part, keeping maintenance simple\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTungsten carbide sleeve bearings for long service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBidirectional design measures flow in either direction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse output adapts readily to many flow computers and readouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eContact Details\u003c\/h3\u003e\n\u003cp\u003eGeneral Tech Services LLC supplies genuine Barton stock in the UAE. Call \u003cstrong\u003e+971 6 5436933\u003c\/strong\u003e for pricing, stock availability and lead time.\u003c\/p\u003e\n\u003ch3\u003eWho This Product Is Best For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eProduction, process and transfer lines in oil and gas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-viscosity liquid measurement where accuracy matters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacing an existing Barton 7000 meter like-for-like\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow to Specify \u0026amp; Install It\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eCheck that your normal and maximum flow fall within 5-50 US GPM and that your liquid suits a turbine meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the meter in straight pipe of the same diameter, with at least 10 diameters of straight run upstream, as specified by Barton.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the pickup coil to your flow computer or readout and enter the meter's K-factor from its calibration certificate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the meter materials, pressure rating and electronics against the Barton datasheet and your process requirements before ordering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the installation and flow direction requirements before putting the meter into service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does a turbine flow meter work?\u003c\/strong\u003e\u003cbr\u003eLiquid turns a balanced rotor; a pickup coil senses each blade and produces pulses in proportion to flow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich liquids suit the Barton 7101?\u003c\/strong\u003e\u003cbr\u003eBarton's 7000 series is designed for low-viscosity liquids, including hydrocarbon liquids. Confirm viscosity and compatibility with our team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow accurate is the Barton 7101?\u003c\/strong\u003e\u003cbr\u003eBarton's series data gives linearity of ±0.25% of reading over the flow range and repeatability of ±0.02% of reading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the meter need straight pipe?\u003c\/strong\u003e\u003cbr\u003eYes. Barton specifies straight pipe of the same diameter with at least 10 diameters upstream for accurate operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose the 7101 or another size?\u003c\/strong\u003e\u003cbr\u003eSize the meter to your flow, not simply the pipe size. The 7101 is listed for 5-50 US GPM. For lower flows, see the Barton 7186. For higher flows, see the Barton 7145. Contact our team to confirm the best option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it measure reverse flow?\u003c\/strong\u003e\u003cbr\u003eThe 7000 series has a symmetrical bidirectional design, and electronic options can sense flow direction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs genuine Barton stock available with UAE shipping?\u003c\/strong\u003e\u003cbr\u003eYes. Genuine Barton stock ships free across the UAE. Call \u003cstrong\u003e+971 6 5436933\u003c\/strong\u003e for current pricing and lead time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e+971 6 5436933\u003c\/strong\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171064433,"sku":"TFM\/7101\/1 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7101-rf-meter-meter-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm-25381832261745.jpg?v=1761752376"},{"product_id":"barton-7145-rf-meter-meter-size-1-1-4-inch-end-connection-size-1-inch-flow-rate-10-80-us-gpm","title":"Barton 7145 RF meter, meter Size :1-1\/4 inch,End Connection Size :1 inch,Flow Rate :10-80 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7145\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7145 is a Cameron BARTON Series 7000 liquid turbine flow meter for hydrocarbon measurement. This 1-1\/4-inch meter covers a flow range of 10–80 US GPM, providing approximately an 8:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. The signal can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7145 has a listed 1-inch end connection size. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, meter and line size, connection requirements, fluid, pressure rating and compatible electronics. The Series 7000 range includes flanged and threaded connection configurations, so the required connection should be confirmed for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city to confirm availability, compatibility and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 10–80 US GPM in a 1-1\/4-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial customers requiring a 1-1\/4-inch liquid turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabia buyers sourcing genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 10–80 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure requirements and connection arrangement before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use a suitable strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow reading at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7145 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7145 covers 10–80 US GPM in a 1-1\/4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7145?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7145 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7145 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7145 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7145 and 7245?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth models are 1-1\/4-inch turbine meters. The Barton 7145 covers 10–80 US GPM and has a listed 1-inch end connection, while the Barton 7245 covers 6–90 US GPM and has a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range and pressure requirements. This helps confirm the appropriate configuration and availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7145 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Contact General Tech Services LLC for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7145 pricing, availability or technical requirements, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171162737,"sku":"TFM\/7145\/1-1\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7145-rf-meter-meter-size-1-1-4-inch-end-connection-size-1-inch-flow-rate-10-80-us-gpm-25381832392817.jpg?v=1761752375"},{"product_id":"barton-7146-rf-meter-meter-size-1-1-2-inch-end-connection-size-1-inch-flow-rate-13-130-us-gpm","title":"Barton 7146 RF meter, meter Size :1-1\/2 inch,End Connection Size :1 inch,Flow Rate :13-130 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7146\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7146 is a Cameron BARTON Series 7000 liquid turbine flow meter for hydrocarbon measurement. This 1-1\/2-inch meter covers a flow range of 13–130 US GPM, providing approximately a 10:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. The signal can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7146 has a listed 1-inch end connection size. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, meter and line size, connection requirements, fluid, pressure rating and compatible electronics. The Series 7000 range includes flanged and threaded connection configurations, so the required connection should be confirmed for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city to confirm availability, compatibility and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 13–130 US GPM in a 1-1\/2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial customers requiring a 1-1\/2-inch liquid turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabia buyers sourcing genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 13–130 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure requirements and connection arrangement before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use a suitable strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow reading at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7146 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7146 covers 13–130 US GPM in a 1-1\/2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7146?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7146 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7146 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7146 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7146 and 7246?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth models are 1-1\/2-inch turbine meters covering 13–130 US GPM. The Barton 7146 has a listed 1-inch end connection, while the Barton 7246 has a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range and pressure requirements. This helps confirm the appropriate configuration and availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7146 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Contact General Tech Services LLC for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7146 pricing, availability or technical requirements, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171228273,"sku":"TFM\/7146\/1-1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7146-rf-meter-meter-size-1-1-2-inch-end-connection-size-1-inch-flow-rate-13-130-us-gpm-25381832458353.jpg?v=1761752375"},{"product_id":"barton-7102-rf-meter-meter-size-2-inch-end-connection-size-1-inch-flow-rate-24-240-us-gpm","title":"Barton 7102 RF meter, meter Size :2 inch,End Connection Size :1 inch,Flow Rate :24-240 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7102\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7102 is a Cameron BARTON Series 7000 liquid turbine flow meter for hydrocarbon measurement. This 2-inch meter covers a flow range of 24–240 US GPM, providing approximately a 10:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. The rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. This output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7102 has a listed 1-inch end connection size. The Series 7000 design supports bidirectional measurement, allowing reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, meter and line size, end-connection requirements, fluid, pressure rating and compatible electronics. The Series 7000 range is available with flanged and threaded connection configurations, so the required connection should be confirmed for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city to confirm availability, compatibility and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 24–240 US GPM in a 2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial customers requiring a 2-inch liquid turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabia buyers sourcing genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 24–240 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure requirements and connection arrangement before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use a suitable strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow reading at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7102 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7102 covers 24–240 US GPM in a 2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7102?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7102 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7102 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7102 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7102 and 7202?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth models are 2-inch turbine meters covering 24–240 US GPM. The Barton 7102 has a listed 1-inch end connection, while the Barton 7202 has a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range and pressure requirements. This helps confirm the appropriate configuration and availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7102 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Contact General Tech Services LLC for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7102 pricing, availability or technical requirements, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171261041,"sku":"TFM\/7102\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7102-rf-meter-meter-size-2-inch-end-connection-size-1-inch-flow-rate-24-240-us-gpm-25381832949873.jpg?v=1761752374"},{"product_id":"barton-7125-flanged-rf-meter-meter-size-2-1-2-inch-end-connection-size-1-inch-flow-rate-44-440-us-gpm","title":"Barton 7125 Flanged RF meter, meter Size :2-1\/2 inch,End Connection Size :1 inch,Flow Rate :44-440 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7125\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7125 is a Cameron BARTON Series 7000 liquid turbine flow meter designed for hydrocarbon measurement. This 2-1\/2-inch meter covers a flow range of 44–440 US GPM, providing approximately a 10:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. Rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and produces a sine-wave signal proportional to flow. The output can be used with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7125 has a listed 1-inch end connection size and is identified as a flanged configuration in the supplied product listing. The Series 7000 design also supports bidirectional measurement, allowing reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the flow range, with ±0.15% available over limited ranges. Repeatability is ±0.02% of reading. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, meter size, line size, end-connection style, fluid, pressure rating and compatible electronics. The meter should be selected according to the actual installation and operating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, required quantity and delivery city so the team can confirm availability, compatibility and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 44–440 US GPM in a 2-1\/2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a like-for-like Barton meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial customers requiring a 2-1\/2-inch liquid turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabia buyers sourcing genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 44–440 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and connection requirements before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use a suitable strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow reading at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7125 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7125 covers 44–440 US GPM in a 2-1\/2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7125?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7125 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7125 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This output can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7125 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7125 and 7103?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7125 is a 2-1\/2-inch meter covering 44–440 US GPM, while the Barton 7103 is a 3-inch meter covering 70–700 US GPM. Both have a listed 1-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range and pressure requirements. This helps confirm the appropriate configuration and availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7125 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Contact General Tech Services LLC for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7125 pricing, availability or technical requirements, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCall +966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171293809,"sku":"TFM\/7125\/2-1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7125-flanged-rf-meter-meter-size-2-1-2-inch-end-connection-size-1-inch-flow-rate-44-440-us-gpm-25381833080945.jpg?v=1761752373"},{"product_id":"barton-7103-flanged-rf-meter-meter-size-3-inch-end-connection-size-1-inch-flow-rate-70-700-us-gpm","title":"Barton 7103 Flanged RF meter, meter Size :3 inch,End Connection Size :1 inch,Flow Rate :70-700 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7103\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7103 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 70–700 US GPM flow range. The 3-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses each passing blade and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7103 provides ±0.25% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 1-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections. The supplied product listing identifies this 7103 configuration as flanged.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 70–700 US GPM in a 3-inch meter size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited flow ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible flow electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupplied configuration identified as flanged\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7103 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading, transfer and terminal operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers requiring genuine Barton instrumentation in Saudi Arabia\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates fall within the 70–700 US GPM range and that the meter size and fluid are suitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection arrangement, pressure rating and installation dimensions before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected flow electronics according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7103 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7103 covers 70–700 US GPM in a 3-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7103?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is ±0.25% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7103 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of output does the meter provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7103 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7103 and 7203?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3-inch turbine meters, but the supplied specifications differ in flow range and listed end connection. The Barton 7103 covers 70–700 US GPM with a listed 1-inch end connection, while the Barton 7203 covers 58–580 US GPM with a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7103 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171359345,"sku":"TFM\/7103\/3 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7103-flanged-rf-meter-meter-size-3-inch-end-connection-size-1-inch-flow-rate-70-700-us-gpm-25381833375857.jpg?v=1761752374"},{"product_id":"barton-7104-flanged-rf-meter-meter-size-4-inch-end-connection-size-1-inch-flow-rate-105-1250-us-gpm","title":"Barton 7104 Flanged RF meter, meter Size :4 inch,End Connection Size :1 inch,Flow Rate :105-1250 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7104\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7104 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 105–1,250 US GPM flow range. The 4-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses each passing blade and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7104 provides ±0.25% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 1-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections. The supplied product listing identifies this 7104 configuration as flanged.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 105–1,250 US GPM in a 4-inch meter size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited flow ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible flow electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupplied configuration identified as flanged\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7104 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading, transfer and terminal operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers requiring genuine Barton instrumentation in Saudi Arabia\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates fall within the 105–1,250 US GPM range and that the meter size and fluid are suitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection arrangement, pressure rating and installation dimensions before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected flow electronics according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7104 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7104 covers 105–1,250 US GPM in a 4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7104?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is ±0.25% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7104 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of output does the meter provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7104 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7104 and 7304?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 4-inch turbine meters, but the supplied specifications differ in flow range and listed end connection. The Barton 7104 covers 105–1,250 US GPM with a listed 1-inch end connection, while the Barton 7304 covers 115–1,150 US GPM with a listed 3-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7104 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171392113,"sku":"TFM\/7104\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7104-flanged-rf-meter-meter-size-4-inch-end-connection-size-1-inch-flow-rate-105-1250-us-gpm-25381833441393.jpg?v=1761752115"},{"product_id":"barton-7108-rf-meter-meter-size-8-inch-end-connection-size-1-inch-flow-rate-540-5400-us-gpm","title":"Barton 7108 RF meter, meter Size :8 inch,End Connection Size :1 inch,Flow Rate :540-5400 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7108\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7108 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 540–5,400 US GPM flow range. The 8-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses each passing blade and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7108 provides ±0.25% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 1-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 540–5,400 US GPM in an 8-inch meter size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited flow ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible flow electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 configuration with flanged or threaded end connections\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7108 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading, transfer and terminal operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers requiring genuine Barton instrumentation in Saudi Arabia\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates fall within the 540–5,400 US GPM range and that the meter size and fluid are suitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection arrangement, pressure rating and installation dimensions before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected flow electronics according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7108 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7108 covers 540–5,400 US GPM in an 8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7108?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is ±0.25% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7108 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of output does the meter provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7108 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7108 and 7308?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 8-inch turbine meters covering 540–5,400 US GPM, but the supplied specifications list different end connection sizes. The Barton 7108 has a listed 1-inch end connection, while the Barton 7308 has a listed 2-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7108 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171490417,"sku":"TFM\/7108\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7108-rf-meter-meter-size-8-inch-end-connection-size-1-inch-flow-rate-540-5400-us-gpm-25381833572465.jpg?v=1761752021"},{"product_id":"barton-7283-rf-meter-meter-size-3-8-inch-end-connection-size-2-inch-flow-rate-0-5-5-us-gpm","title":"Barton 7283 RF meter, meter Size :3\/8 inch,End Connection Size :2 inch,Flow Rate :0.5-5 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7283\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7283 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 0.5–5 US GPM flow range. The 3\/8-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses each passing blade and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7283 provides ±1% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%. The 7200 model configuration uses self-lubricating precision stainless steel bearings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 2-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 0.5–5 US GPM in a 3\/8-inch meter size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited flow ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible flow electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7283 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading, transfer and terminal operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers requiring genuine Barton instrumentation in Saudi Arabia\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates fall within the 0.5–5 US GPM range and that the meter size and fluid are suitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection arrangement, pressure rating and installation dimensions before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected flow electronics according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7283 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7283 covers 0.5–5 US GPM in a 3\/8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7283?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is ±1% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7283 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of output does the meter provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7283 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7283 and 7183?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3\/8-inch turbine meters, but the supplied specifications differ in flow range and listed end connection. The Barton 7283 covers 0.5–5 US GPM with a listed 2-inch end connection, while the Barton 7183 covers 0.45–4 US GPM with a listed 1-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7283 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171523185,"sku":"TFM\/7283\/3\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7283-rf-meter-meter-size-3-8-inch-end-connection-size-2-inch-flow-rate-0-5-5-us-gpm-25381833834609.jpg?v=1761752114"},{"product_id":"barton-7284-rf-meter-meter-size-1-2-inch-end-connection-size-2-inch-flow-rate-1-10-us-gpm","title":"Barton 7284 RF meter, meter Size :1\/2 inch,End Connection Size :2 inch,Flow Rate :1-10 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7284\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7284 turbine flow meter is a Cameron BARTON Series 7000 liquid turbine meter designed for liquid flow measurement across a 1–10 US GPM flow range. The 1\/2-inch meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow. A pickup senses the passing turbine blades and generates a sine-wave signal proportional to flow for use with compatible preamplifiers, digital readouts, totalizers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7284 provides ±1% of reading linearity over its stated flow range and ±0.02% repeatability. Over limited flow ranges, linearity can reach ±0.15%. The 7200 model configuration uses self-lubricating precision stainless steel bearings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter has a listed 2-inch end connection size, while Series 7000 configurations are available with flanged and threaded connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics interface. General Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 1–10 US GPM in a 1\/2-inch meter size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited flow ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible flow electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible with digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7284 is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading, transfer and terminal operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers requiring genuine Barton instrumentation in Saudi Arabia\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates fall within the 1–10 US GPM range and that the meter size and fluid are suitable.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection arrangement, pressure rating and installation dimensions before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe length upstream and downstream. A strainer can be used where debris may be present in the liquid line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, flow computer or other receiving electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected flow electronics according to the meter documentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7284 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7284 covers 1–10 US GPM in a 1\/2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7284?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is ±1% of reading over the stated flow range, with ±0.15% linearity available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7284 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of output does the meter provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7284 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7284 and 7184?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 1\/2-inch turbine meters, but the supplied specifications differ in flow range and listed end connection. The Barton 7284 covers 1–10 US GPM with a listed 2-inch end connection, while the Barton 7184 covers 0.88–8.2 US GPM with a listed 1-inch end connection. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with application details such as fluid type, normal and maximum flow, pressure requirements and connection requirements. This allows the required configuration to be checked.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7284 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or technical compatibility, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171555953,"sku":"TFM\/7284\/1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7284-rf-meter-meter-size-1-2-inch-end-connection-size-2-inch-flow-rate-1-10-us-gpm-25381833900145.jpg?v=1761752020"},{"product_id":"barton-7285-rf-meter-meter-size-5-8-inch-end-connection-size-2-inch-flow-rate-1-6-16-us-gpm","title":"Barton 7285 RF meter, meter Size :5\/8 inch,End Connection Size :2 inch,Flow Rate :1.6-16 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7285\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7285 is a 5\/8-inch Cameron BARTON Series 7000 liquid turbine flow meter covering a 1.6–16 US GPM flow range. It is designed for liquid measurement applications where the turbine meter provides a proportional flow signal for compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. The rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and generates a sine-wave signal corresponding to flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7285 has a listed 2-inch end connection size and provides approximately a 10:1 flow range. Rated linearity is ±1% of reading over the stated flow range, with ±0.15% of reading over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and connected electronics. Series 7000 meters are available with flanged and threaded connection configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city when requesting a quotation so availability and pricing can be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 1.6–16 US GPM in a 5\/8-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 design with flanged and threaded connection configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7285 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCrude and refined product transfer lines\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use an appropriate strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and enter the applicable meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter output at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the complete installation and connected electronics before placing the meter into routine service.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7285 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7285 covers 1.6–16 US GPM and has a 5\/8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7285?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7285 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7285 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup generates a sine-wave signal proportional to liquid flow. This output can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7285 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7285 and 7185?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 5\/8-inch turbine meters covering 1.6–16 US GPM. The Barton 7285 has a listed 2-inch end connection, while the Barton 7185 has a listed 1-inch end connection. Selection should be based on the required flow range and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range, pressure conditions, line size and connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7285 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171588721,"sku":"TFM\/7285\/5\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7285-rf-meter-meter-size-5-8-inch-end-connection-size-2-inch-flow-rate-1-6-16-us-gpm-25381833998449.jpg?v=1761752019"},{"product_id":"barton-7286-rf-meter-meter-size-3-4-inch-end-connection-size-2-inch-flow-rate-2-3-23-us-gpm","title":"Barton 7286 RF meter, meter Size :3\/4 inch,End Connection Size :2 inch,Flow Rate :2.3-23 US GPM","description":"\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7286\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7286 is a 3\/4-inch Cameron BARTON Series 7000 liquid turbine flow meter covering a 2.3–23 US GPM flow range. It is designed for liquid measurement applications where the turbine meter provides a proportional flow signal for compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. The rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and generates a sine-wave signal corresponding to flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7286 has a listed 2-inch end connection size and provides approximately a 10:1 flow range. Rated linearity is ±1% of reading over the stated flow range, with ±0.15% of reading over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and connected electronics. Series 7000 meters are available with flanged and threaded connection configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city when requesting a quotation so availability and pricing can be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 2.3–23 US GPM in a 3\/4-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±1% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 design with flanged and threaded connection configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7286 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCrude and refined product transfer lines\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use an appropriate strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and enter the applicable meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter output at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the complete installation and connected electronics before placing the meter into routine service.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7286 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7286 covers 2.3–23 US GPM and has a 3\/4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7286?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±1% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7286 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7286 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup generates a sine-wave signal proportional to liquid flow. This output can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7286 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7286 and 7186?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3\/4-inch turbine meters covering 2.3–23 US GPM. The Barton 7286 has a listed 2-inch end connection, while the Barton 7186 has a listed 1-inch end connection. Selection should be based on the required flow range and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range, pressure conditions, line size and connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7286 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171654257,"sku":"TFM\/7286\/3\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7286-rf-meter-meter-size-3-4-inch-end-connection-size-2-inch-flow-rate-2-3-23-us-gpm-25381834391665.jpg?v=1761752018"},{"product_id":"barton-7201-rf-meter-meter-size-1-inch-end-connection-size-2-inch-flow-rate-5-50-us-gpm","title":"Barton 7201 RF meter, meter Size :1 inch,End Connection Size :2 inch,Flow Rate :5-50 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7201\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7201 is a 1-inch Cameron BARTON Series 7000 liquid turbine flow meter covering a 5–50 US GPM flow range. It is designed for liquid measurement applications where the turbine meter provides a proportional flow signal for compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto a multi-blade turbine rotor. The rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and generates a sine-wave signal corresponding to flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7201 has a listed 2-inch end connection size and provides approximately a 10:1 flow range. Rated linearity is ±0.25% of reading over the stated flow range, with ±0.15% of reading over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and connected electronics. Series 7000 meters are available with flanged and threaded connection configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city when requesting a quotation so availability and pricing can be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 5–50 US GPM in a 1-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 design with flanged and threaded connection configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7201 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCrude and refined product transfer lines\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use an appropriate strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and enter the applicable meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter output at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the complete installation and connected electronics before placing the meter into routine service.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7201 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7201 covers 5–50 US GPM and has a 1-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7201?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7201 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7201 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup generates a sine-wave signal proportional to liquid flow. This output can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7201 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7201 and 7101?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 1-inch turbine meters covering 5–50 US GPM. The Barton 7201 has a listed 2-inch end connection, while the Barton 7101 has a listed 1-inch end connection. Selection should be based on the required flow range and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range, pressure conditions, line size and connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7201 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171687025,"sku":"TFM\/7201\/1 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7201-rf-meter-meter-size-1-inch-end-connection-size-2-inch-flow-rate-5-50-us-gpm-25381834719345.jpg?v=1761752019"},{"product_id":"barton-7245-rf-meter-meter-size-1-1-4-inch-end-connection-size-2-inch-flow-rate-6-90-us-gpm","title":"Barton 7245 RF meter, meter Size :1-1\/4 inch ,End Connection Size :2 inch,Flow Rate :6-90 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7245\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7245 is a 1-1\/4-inch Cameron BARTON Series 7000 liquid turbine flow meter covering a 6–90 US GPM flow range. It is designed for liquid measurement applications where a turbine meter provides a proportional flow signal for compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser onto the multi-blade turbine rotor. Rotor speed is proportional to the liquid flow rate, while a pickup senses each blade tip and generates a sine-wave signal corresponding to flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7245 has a listed 2-inch end connection size and provides an approximately 15:1 flow range. Rated linearity is ±0.25% of reading over the stated flow range, with ±0.15% of reading over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Compatible accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and connected electronics. Series 7000 meters are available with flanged and threaded connection configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Provide the part number, quantity and delivery city when requesting a quotation so availability and pricing can be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 6–90 US GPM in a 1-1\/4-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 design with flanged and threaded connection configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7245 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCrude and refined product transfer lines\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial buyers in Saudi Arabia requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are compatible with the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Use an appropriate strainer where debris may be present.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and enter the applicable meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the meter output at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the complete installation and connected electronics before placing the meter into routine service.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7245 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7245 covers 6–90 US GPM and has a 1-1\/4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7245?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7245 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7245 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup generates a sine-wave signal proportional to liquid flow. This output can be used with compatible preamplifiers, totalizers, digital readouts and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7245 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include product transfer, loading operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7245 and 7145?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 1-1\/4-inch turbine meters, but their listed flow and connection specifications differ. The Barton 7245 covers 6–90 US GPM and has a listed 2-inch end connection, while the Barton 7145 covers 10–80 US GPM and has a listed 1-inch end connection. Selection should be based on the required flow range and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, together with relevant application details such as fluid, required flow range, pressure conditions, line size and connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7245 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171785329,"sku":"TFM\/7245\/1-1\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7245-rf-meter-meter-size-1-1-4-inch-end-connection-size-2-inch-flow-rate-6-90-us-gpm-25381834784881.jpg?v=1761752018"},{"product_id":"barton-7246-rf-meter-meter-size-1-1-2-inch-end-connection-size-2-inch-flow-rate-13-130-us-gpm","title":"Barton 7246 RF meter, meter Size :1-1\/2 inch,End Connection Size :2 inch,Flow Rate :13-130 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton instruments from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7246\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7246 is a 1-1\/2-inch Cameron BARTON Series 7000 liquid turbine flow meter designed for precise liquid measurement across a 13–130 US GPM flow range. The meter uses a multi-blade turbine rotor, with rotor speed proportional to liquid flow rate. A pickup senses the passing turbine blades and generates a sine-wave signal proportional to flow for use with compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7246 has a listed 2-inch end connection size and provides approximately a 10:1 flow range. Rated linearity is ±0.25% of reading across the flow range, with ±0.15% of reading available over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAs a 7200-series model, the 7246 uses self-lubricating precision stainless steel bearings. Its symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and compatible electronics. The Series 7000 range is available with flanged and threaded connection configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, required quantity and delivery city when requesting a quotation so availability and pricing can be confirmed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 13–130 US GPM in a 1-1\/2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeries 7000 design with flanged and threaded connection configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7246 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCrude and refined product transfer lines\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoading and transfer skids\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical injection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian industrial buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 13–130 US GPM range and verify the line size and fluid compatibility.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream. Where debris may be present, use an appropriate strainer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer and enter the applicable meter K-factor.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the output at normal operating flow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the complete installation and connected electronics before placing the meter into routine service.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7246 cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7246 covers 13–130 US GPM and has a 1-1\/2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7246?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRated linearity is ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7246 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. Its symmetrical, bidirectional Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7246 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. It can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7246 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7246 and 7146?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth models are 1-1\/2-inch meters covering 13–130 US GPM. The Barton 7246 has a listed 2-inch end connection, while the Barton 7146 has a listed 1-inch end connection. Selection should be based on the required flow range, meter size and installation connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with relevant application information such as fluid, required flow range, pressure conditions, line size and connection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7246 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing, availability or ordering assistance, contact General Tech Services LLC, Saudi Office, Dammam.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171818097,"sku":"TFM\/7246\/1-1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7246-rf-meter-meter-size-1-1-2-inch-end-connection-size-2-inch-flow-rate-13-130-us-gpm-25381834850417.jpg?v=1761752018"},{"product_id":"barton-7202-rf-meter-meter-size-2-inch-end-connection-size-2-inch-flow-rate-24-240-us-gpm","title":"Barton 7202 RF meter, meter Size :2 inch,End Connection Size :2 inch,Flow Rate :24-240 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7202 turbine flow meter is a 2-inch Cameron BARTON® Series 7000 liquid turbine meter covering 24–240 US GPM. It provides ±0.25% of reading linearity over the flow range and ±0.02% repeatability. Genuine Barton instruments are available from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7202\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7202 turbine flow meter is part of Cameron's BARTON® Series 7000 range of turbine meters designed for liquid measurement. Liquid passes through a diffuser onto a multi-blade turbine rotor, with rotor speed proportional to flow rate. A pickup senses each blade tip and produces a sine-wave signal proportional to flow, making the meter suitable for connection to digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7202 has a 2-inch meter size and a listed 2-inch end connection size. Its flow range is 24–240 US GPM, providing an approximately 10:1 range. Rated linearity is ±0.25% of reading over the flow range and ±0.15% over limited ranges, with repeatability of ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, line size, fluid, pressure rating, end-connection style and electronics that will be connected to the meter. The applicable meter K-factor should also be entered into the associated flow instrumentation during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services LLC supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city with our team to confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a different 2-inch configuration, the Barton 7102 is listed with a 24–240 US GPM flow range and a 1-inch end connection size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e24–240 US GPM flow range in a 2-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% of reading repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings for 7200 models\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlanged and threaded connection configurations available within the Series 7000 range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing and lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7202 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial users replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams working with existing Barton Series 7000 installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 24–240 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and required connection configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a suitable strainer where debris in the liquid line could affect the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Series 7000 installation documentation and site procedures for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7202 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7202 covers 24–240 US GPM in a 2-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7202?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated linearity is ±0.25% of reading over the flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7202 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of bearings does the Barton 7202 use?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7202 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7202 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7202 and 7102?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 2-inch Barton turbine meters with a listed flow range of 24–240 US GPM. The Barton 7202 has a listed 2-inch end connection size, while the Barton 7102 has a listed 1-inch end connection size. Selection should be based on the required connection configuration and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid type, required flow range, pressure requirements, line size and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7202 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7202 pricing, availability or technical compatibility, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171850865,"sku":"TFM\/7202\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7202-rf-meter-meter-size-2-inch-end-connection-size-2-inch-flow-rate-24-240-us-gpm-25381834915953.jpg?v=1761752017"},{"product_id":"barton-7203-rf-meter-meter-size-3-inch-end-connection-size-2-inch-flow-rate-58-580-us-gpm","title":"Barton 7203 RF meter, meter Size :3 inch,End Connection Size :2 inch,Flow Rate :58-580 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7203 turbine flow meter is a 3-inch Cameron BARTON® Series 7000 liquid turbine meter covering 58–580 US GPM. It provides ±0.25% of reading linearity over the flow range and ±0.02% repeatability. Genuine Barton instruments are available from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7203\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7203 turbine flow meter is part of Cameron's BARTON® Series 7000 range of turbine meters designed for liquid measurement. Liquid passes through a diffuser onto a multi-blade turbine rotor, with rotor speed proportional to flow rate. A pickup senses each blade tip and produces a sine-wave signal proportional to flow, making the meter suitable for connection to digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7203 has a 3-inch meter size and a listed 2-inch end connection size. Its flow range is 58–580 US GPM, providing an approximately 10:1 range. Rated linearity is ±0.25% of reading over the flow range and ±0.15% over limited ranges, with repeatability of ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings. The symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, line size, fluid, pressure rating, end-connection style and electronics that will be connected to the meter. The applicable meter K-factor should also be entered into the associated flow instrumentation during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services LLC supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city with our team to confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a different 3-inch configuration, the Barton 7103 is listed with a 70–700 US GPM flow range and a 1-inch end connection size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e58–580 US GPM flow range in a 3-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% of reading repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelf-lubricating precision stainless steel bearings for 7200 models\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlanged and threaded connection configurations available within the Series 7000 range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing and lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7203 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial users replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams working with existing Barton Series 7000 installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 58–580 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and required connection configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a suitable strainer where debris in the liquid line could affect the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Series 7000 installation documentation and site procedures for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7203 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7203 covers 58–580 US GPM in a 3-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7203?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated linearity is ±0.25% of reading over the flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7203 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat type of bearings does the Barton 7203 use?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 7200 models use self-lubricating precision stainless steel bearings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7203 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7203 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7203 and 7103?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 3-inch Barton turbine meters. The Barton 7203 covers 58–580 US GPM and has a listed 2-inch end connection size. The Barton 7103 is listed with a 70–700 US GPM flow range and a 1-inch end connection size. Selection should be based on the required flow range, connection configuration and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid type, required flow range, pressure requirements, line size and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7203 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7203 pricing, availability or technical compatibility, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171916401,"sku":"TFM\/7203\/3 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7203-rf-meter-meter-size-3-inch-end-connection-size-2-inch-flow-rate-58-580-us-gpm-25381834981489.jpg?v=1761752017"},{"product_id":"barton-7304-rf-meter-meter-size-4-inch-end-connection-size-3-inch-flow-rate-115-1150-us-gpm","title":"Barton 7304 RF meter, meter Size :4 inch,End Connection Size :3 inch,Flow Rate :115-1150 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7304 turbine flow meter is a 4-inch Cameron BARTON® Series 7000 liquid turbine meter covering 115–1,150 US GPM. It provides ±0.25% of reading linearity over the flow range and ±0.02% repeatability. Genuine Barton instruments are available from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7304\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7304 turbine flow meter is part of Cameron's BARTON® Series 7000 range of turbine meters designed for liquid measurement. Liquid passes through a diffuser onto a multi-blade turbine rotor, with rotor speed proportional to flow rate. A pickup senses each blade tip and produces a sine-wave signal proportional to flow, making the meter suitable for connection to digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7304 has a 4-inch meter size and a listed 3-inch end connection size. Its flow range is 115–1,150 US GPM, providing an approximately 10:1 range. Rated linearity is ±0.25% of reading over the flow range and ±0.15% over limited ranges, with repeatability of ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Series 7000 range is available with flanged and threaded connection configurations. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, line size, fluid, pressure rating, end-connection style and electronics that will be connected to the meter. The applicable meter K-factor should also be entered into the associated flow instrumentation during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services LLC supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city with our team to confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a different 4-inch configuration, the Barton 7104 is listed with a 105–1,250 US GPM flow range and a 1-inch end connection size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e115–1,150 US GPM flow range in a 4-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% of reading repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlanged and threaded connection configurations available within the Series 7000 range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing and lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7304 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial users replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams working with existing Barton Series 7000 installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 115–1,150 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and required connection configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a suitable strainer where debris in the liquid line could affect the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Series 7000 installation documentation and site procedures for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7304 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7304 covers 115–1,150 US GPM in a 4-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7304?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated linearity is ±0.25% of reading over the flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7304 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7304 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7304 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7304 and 7104?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 4-inch Barton turbine meters. The Barton 7304 covers 115–1,150 US GPM and has a listed 3-inch end connection size. The Barton 7104 is listed with a 105–1,250 US GPM flow range and a 1-inch end connection size. Selection should be based on the required flow range, connection configuration and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid type, required flow range, pressure requirements, line size and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7304 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7304 pricing, availability or technical compatibility, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170171949169,"sku":"TFM\/7304\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7304-rf-meter-meter-size-4-inch-end-connection-size-3-inch-flow-rate-115-1150-us-gpm-25381835047025.jpg?v=1761752016"},{"product_id":"barton-7306-rf-meter-meter-size-6-inch-end-connection-size-2-inch-flow-rate-250-2250-us-gpm","title":"Barton 7306 RF meter, meter Size :6 inch,End Connection Size :2 inch,Flow Rate :250-2250 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7306 turbine flow meter is a 6-inch Cameron BARTON® Series 7000 liquid turbine meter covering 250–2,250 US GPM. It provides ±0.25% of reading linearity over the flow range and ±0.02% repeatability. Genuine Barton instruments are available from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7306\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7306 turbine flow meter is part of Cameron's BARTON® Series 7000 range of turbine meters designed for liquid measurement. Liquid passes through a diffuser onto a multi-blade turbine rotor, with rotor speed proportional to flow rate. A pickup senses each blade tip and produces a sine-wave signal proportional to flow, making the meter suitable for connection to digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7306 has a 6-inch meter size and a listed 2-inch end connection size. Its flow range is 250–2,250 US GPM, providing an approximately 9:1 range. Rated linearity is ±0.25% of reading over the flow range and ±0.15% over limited ranges, with repeatability of ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Series 7000 range is available with flanged and threaded connection configurations. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required normal and maximum flow rates, line size, fluid, pressure rating, end-connection style and electronics that will be connected to the meter. The applicable meter K-factor should also be entered into the associated flow instrumentation during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services LLC supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city with our team to confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a different flow range or connection configuration, see the Barton 7106 turbine flow meter, an 8-inch? No — the supplied 7106 data identifies it as a 6-inch meter covering 250–2,500 US GPM with a listed 1-inch end connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e250–2,250 US GPM flow range in a 6-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% of reading repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlanged and threaded connection configurations available within the Series 7000 range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing and lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7306 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial users replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams working with existing Barton Series 7000 installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 250–2,250 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and required connection configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a suitable strainer where debris in the liquid line could affect the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Series 7000 installation documentation and site procedures for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7306 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7306 covers 250–2,250 US GPM in a 6-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7306?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated linearity is ±0.25% of reading over the flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7306 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7306 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7306 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7306 and 7106?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 6-inch Barton turbine meters with a stated flow range beginning at 250 US GPM. The Barton 7306 covers 250–2,250 US GPM and has a listed 2-inch end connection size. The Barton 7106 covers 250–2,500 US GPM and has a listed 1-inch end connection size. Selection should be based on the required flow range, connection configuration and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid type, required flow range, pressure requirements, line size and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7306 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7306 pricing, availability or technical compatibility, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170172014705,"sku":"TFM\/7306\/6 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7306-rf-meter-meter-size-6-inch-end-connection-size-2-inch-flow-rate-250-2250-us-gpm-25381835374705.jpg?v=1761752014"},{"product_id":"barton-7308-rf-meter-meter-size-8-inch-end-connection-size-2-inch-flow-rate-540-5400-us-gpm","title":"Barton 7308 RF meter, meter Size :8 inch,End Connection Size :2 inch,Flow Rate :540-5400 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7308 turbine flow meter is an 8-inch Cameron BARTON® Series 7000 liquid turbine meter covering 540–5,400 US GPM. It provides ±0.25% of reading linearity over the flow range and ±0.02% repeatability. Genuine Barton instruments are available from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7308\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7308 turbine flow meter is part of Cameron's BARTON® Series 7000 range of turbine meters designed for liquid measurement. Liquid passes through a diffuser onto a multi-blade turbine rotor, with rotor speed proportional to flow rate. A pickup senses each blade tip and produces a sine-wave signal proportional to flow, making the meter suitable for connection to digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7308 has an 8-inch meter size and a listed 2-inch end connection size. Its flow range is 540–5,400 US GPM, providing an approximately 10:1 range. Rated linearity is ±0.25% of reading over the flow range and ±0.15% over limited ranges, with repeatability of ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The listed application is hydrocarbon measurement, with typical uses including crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Series 7000 range is available with flanged and threaded connection configurations. Matching accessories can include meter runs, preamplifiers, totalizers, connectors and cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm the required flow range, line size, fluid, pressure rating, end-connection style and electronics that will be connected to the meter. The meter's K-factor should also be entered into the associated flow instrumentation during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services LLC supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city with our team to confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e540–5,400 US GPM flow range in an 8-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% of reading repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical bidirectional design for reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible digital instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON® Series 7000 liquid turbine meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlanged and threaded connection configurations available within the Series 7000 range\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor pricing and lead time, call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7308 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineering teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial users replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams working with existing Barton Series 7000 installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSaudi Arabian buyers requiring genuine Barton instrumentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required normal and maximum flow rates are within the 540–5,400 US GPM range.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the meter size, line size, fluid characteristics, pressure rating and required connection configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended straight pipe arrangement upstream and downstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a suitable strainer where debris in the liquid line could affect the meter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected instrumentation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways follow the applicable Series 7000 installation documentation and site procedures for the specific installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7308 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7308 covers 540–5,400 US GPM in an 8-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7308?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stated linearity is ±0.25% of reading over the flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7308 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7308 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This signal can be used with compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7308 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer operations, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7308 and 7108?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBoth are 8-inch Barton turbine meters covering 540–5,400 US GPM. The Barton 7308 has a listed 2-inch end connection size, while the Barton 7108 has a listed 1-inch end connection size. Selection should be based on the required flow range, meter configuration and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with application details such as fluid type, required flow range, pressure requirements, line size and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7308 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7308 pricing, availability or technical compatibility, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170172113009,"sku":"TFM\/7308\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7308-rf-meter-meter-size-8-inch-end-connection-size-2-inch-flow-rate-540-5400-us-gpm-25381835440241.jpg?v=1761752014"},{"product_id":"barton-7310-rf-meter-meter-size-10-inch-end-connection-size-2-inch-flow-rate-800-8000-us-gpm","title":"Barton 7310 RF meter, meter Size :10 inch,End Connection Size :2 inch,Flow Rate :800-8000 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton 7310 turbine flow meter from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7310\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7310 is a 10-inch liquid turbine flow meter from the Cameron BARTON Series 7000 range, designed for precise liquid flow measurement in hydrocarbon applications. It covers a flow range of 800–8,000 US GPM, providing approximately a 10:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser and onto a multi-blade turbine rotor. The rotor speed is proportional to the flow rate, while a pickup senses each blade tip and produces a sine-wave signal corresponding to flow. This output is suitable for connection to compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7310 has a listed 10-inch meter size and a 2-inch end connection size. Rated linearity is ±0.25% of reading over the stated flow range, tightening to ±0.15% over limited ranges, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe symmetrical, bidirectional design supports reverse-flow applications without reducing the stated accuracy or capacity. The meter is listed for hydrocarbon measurement and can be used in applications such as crude and refined product lines, loading and transfer skids, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMatching accessories, including meter runs, preamplifiers, totalizers, connectors and cables, are available. Before ordering, confirm that normal and maximum flow requirements are within the meter's range. Also check the line size, end-connection style, fluid, pressure rating and electronics that will be connected to the pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and the team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 800–8,000 US GPM in a 10-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApproximately 10:1 flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible measurement electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 turbine-meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7310 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and product-transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow-meter integration projects using totalizers or flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuyers in Saudi Arabia requiring genuine Barton flow measurement equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are suitable for the Barton 7310.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection configuration and pressure rating before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended upstream and downstream straight-pipe arrangement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFit a suitable strainer where debris in the liquid could affect the turbine or meter operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, digital readout or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the output and recorded flow against the commissioning requirements for the installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7310 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7310 covers 800–8,000 US GPM in a 10-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7310?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is rated at ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7310 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7310 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This output can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7310 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include crude and refined product lines, product transfer, loading, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the listed end connection size?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied product information lists a 2-inch end connection size for the Barton 7310. The Series 7000 range references flanged and threaded connection configurations, so the exact arrangement should be confirmed before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the difference between the Barton 7310 and 7312?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7310 is a 10-inch meter covering 800–8,000 US GPM, while the Barton 7312 is a 12-inch meter covering 1,250–12,500 US GPM. Both are listed with a 2-inch end connection size. Selection should be based on the required flow range, meter size and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with the fluid, required flow range, line size, pressure rating and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7310 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7310 pricing, availability or ordering support, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170172145777,"sku":"TFM\/7310\/10 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7310-rf-meter-meter-size-10-inch-end-connection-size-2-inch-flow-rate-800-8000-us-gpm-25381835505777.jpg?v=1761752014"},{"product_id":"barton-7312-rf-meter-meter-size-12-inch-end-connection-size-2-inch-flow-rate-1250-12500-us-gpm","title":"Barton 7312 RF meter, meter Size :12 inch ,End Connection Size :2 inch,Flow Rate :1250-12500 US GPM","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenuine Barton 7312 turbine flow meter from General Tech Services LLC, Saudi Arabia, with free Saudi Arabia shipping available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart No. 7312\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7312 is a 12-inch liquid turbine flow meter from the Cameron BARTON Series 7000 range, designed for precise liquid flow measurement in hydrocarbon applications. It covers a flow range of 1,250–12,500 US GPM, providing approximately a 10:1 flow range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLiquid passes through a diffuser and onto a multi-blade turbine rotor. The rotor speed is proportional to the flow rate, while a pickup senses each blade tip and produces a sine-wave signal corresponding to flow. The output can be connected to compatible digital readouts, totalizers, preamplifiers and flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7312 has a listed 12-inch meter size and a 2-inch end connection size. Its rated linearity is ±0.25% of reading over the stated flow range, tightening to ±0.15% over limited ranges, with ±0.02% repeatability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe symmetrical Series 7000 design supports bidirectional operation, allowing the meter to handle reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical applications include crude and refined product lines, loading and transfer skids, chemical injection and allocation metering. Matching accessories such as meter runs, preamplifiers, totalizers, connectors and cables are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, confirm that normal and maximum flow requirements fall within the meter's range. Also check the line size, required end-connection style, fluid, pressure rating and electronics to be connected to the pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGeneral Tech Services supplies genuine Barton instruments to industrial customers across Saudi Arabia from its Dammam office. Share the part number, quantity and delivery city, and the team can confirm compatibility, availability and pricing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMeasures 1,250–12,500 US GPM in a 12-inch meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eApproximately 10:1 flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.25% of reading linearity over the stated flow range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.15% linearity over limited ranges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e±0.02% repeatability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSymmetrical design supports reverse-flow applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSine-wave pickup output for compatible measurement electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for digital readouts, totalizers and flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCameron BARTON Series 7000 turbine-meter design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for hydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFree Saudi Arabia shipping available\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWho This Product Is Best For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7312 is suited to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOil and gas metering and allocation teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal, loading and transfer operations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHydrocarbon measurement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess and instrumentation engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance teams replacing a compatible Barton turbine meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow-meter integration projects using totalizers or flow computers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuyers in Saudi Arabia requiring genuine Barton flow measurement equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHow to Install \u0026amp; Use It\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the required flow range, line size and fluid are suitable for the Barton 7312.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify the required end-connection configuration and pressure rating before installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the meter with the recommended upstream and downstream straight-pipe arrangement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFit a suitable strainer where debris in the liquid could affect the turbine or meter operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnect the pickup to the compatible preamplifier, totalizer, digital readout or flow computer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnter the applicable meter K-factor into the connected electronics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFill the line gradually and verify the flow indication at normal operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck the output and recorded flow against the commissioning requirements for the installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat flow range does the Barton 7312 turbine flow meter cover?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Barton 7312 covers 1,250–12,500 US GPM in a 12-inch meter size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow accurate is the Barton 7312?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLinearity is rated at ±0.25% of reading over the stated flow range, with ±0.15% over limited ranges. Repeatability is ±0.02% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eCan the Barton 7312 measure reverse flow?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The symmetrical Series 7000 design supports reverse-flow applications without reducing the stated accuracy or capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat output does the Barton 7312 provide?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pickup produces a sine-wave signal proportional to flow. This output can be connected to compatible preamplifiers, totalizers, digital readouts or flow computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the Barton 7312 used for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed application is hydrocarbon measurement. Typical uses include product transfer, loading, crude and refined product lines, chemical injection and allocation metering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat is the listed end connection size?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied product information lists a 2-inch end connection size for the Barton 7312. The Series 7000 range also references flanged and threaded connection configurations, so the required arrangement should be confirmed before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eWhat information should I provide when requesting a quote?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvide the model number, quantity and delivery city, along with the fluid, required flow range, line size, pressure rating and connection requirements. This helps confirm the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eHow much does the Barton 7312 cost?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePricing is quote-based. Call \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for current pricing and lead-time information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRequest a Quote Today\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor Barton 7312 pricing, availability or ordering support, contact General Tech Services LLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCall \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e+966 569 289 544\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e | \u003c\/span\u003e\u003ca href=\"http:\/\/www.generaltechshop.sa\"\u003e\u003cspan\u003ewww.generaltechshop.sa\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Barton","offers":[{"title":"Default Title","offer_id":42170172538993,"sku":"TFM\/7312\/12 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/barton-turbine-flow-meters-default-title-barton-7312-rf-meter-meter-size-12-inch-end-connection-size-2-inch-flow-rate-1250-12500-us-gpm-25381835571313.jpg?v=1761752014"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-3-3-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :3\/8 inch,End Connection Size :1 inch,Flow Rate :0.3-3 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172571761,"sku":"TFM\/EZ-IN\/3\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-3-3-us-gpm-25381835669617.png?v=1761752013"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-1-2inch-end-connection-size-1inch-flow-rate-0-75-7-5-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :1\/2inch,End Connection Size :1inch,Flow Rate :0.75-7.5 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172637297,"sku":"TFM\/EZ-IN\/1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-1-2inch-end-connection-size-1inch-flow-rate-0-75-7-5-us-gpm-25381835735153.png?v=1761752012"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-15-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :3\/4 inch,End Connection Size :1 inch,Flow Rate :2-15 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172670065,"sku":"TFM\/EZ-IN\/3\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-15-us-gpm-25381836685425.png?v=1761752013"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-7-8inch-end-connection-size-1-inch-flow-rate-3-30-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :7\/8inch,End Connection Size :1 inch,Flow Rate :3-30 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172768369,"sku":"TFM\/EZ-IN\/7\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-7-8inch-end-connection-size-1-inch-flow-rate-3-30-us-gpm-25381836750961.png?v=1761752009"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :1 inch,End Connection Size :1 inch,Flow Rate :5-50 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172801137,"sku":"TFM\/EZ-IN\/1 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm-25381836816497.png?v=1761752009"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-3-8-inch-end-connection-size-2-inch-flow-rate-0-3-3-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :3\/8 inch,End Connection Size :2 inch,Flow Rate :0.3-3 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172833905,"sku":"TFM\/EZ-IN\/3\/8  inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-3-8-inch-end-connection-size-2-inch-flow-rate-0-3-3-us-gpm-25381836882033.png?v=1761752009"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-1-1-2-inch-end-connection-size-2-inch-flow-rate-15-180-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :1-1\/2 inch,End Connection Size :2 inch,Flow Rate :15-180 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172866673,"sku":"TFM\/EZ-IN\/1-1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-1-1-2-inch-end-connection-size-2-inch-flow-rate-15-180-us-gpm-25381836980337.png?v=1761752008"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-2-inch-end-connection-size-2-inch-flow-rate-40-400-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :2 inch,End Connection Size :2 inch,Flow Rate :40-400 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172899441,"sku":"TFM\/EZ-IN\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-2-inch-end-connection-size-2-inch-flow-rate-40-400-us-gpm-25381837209713.png?v=1761752009"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-3-inch-end-connection-size-3-inch-flow-rate-80-800-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :3 inch,End Connection Size :3 inch,Flow Rate :80-800 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172932209,"sku":"TFM\/EZ-IN\/3 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-3-inch-end-connection-size-3-inch-flow-rate-80-800-us-gpm-25381837308017.png?v=1761752009"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-4-inch-end-connection-size-4-inch-flow-rate-100-1200-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :4 inch,End Connection Size :4 inch,Flow Rate :100-1200 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170172964977,"sku":"TFM\/EZ-IN\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-4-inch-end-connection-size-4-inch-flow-rate-100-1200-us-gpm-25381837439089.png?v=1761752008"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-6-inch-end-connection-size-6-inch-flow-rate-250-2500-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :6 inch,End Connection Size :6 inch,Flow Rate :250-2500 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173030513,"sku":"TFM\/EZ-IN\/6 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-6-inch-end-connection-size-6-inch-flow-rate-250-2500-us-gpm-25381837504625.png?v=1761752007"},{"product_id":"nuflo-liquid-ez-in-rf-meter-line-size-8-inch-end-connection-size-8-inch-flow-rate-350-3500-us-gpm","title":"Nuflo Liquid EZ-IN RF meter, Line Size :8 inch,End Connection Size :8 inch,Flow Rate :350-3500 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173063281,"sku":"TFM\/EZ-IN\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-ez-in-rf-meter-line-size-8-inch-end-connection-size-8-inch-flow-rate-350-3500-us-gpm-25381837602929.png?v=1761752004"},{"product_id":"nuflo-liquid-npt-meter-line-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-3-3-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :3\/8 inch,End Connection Size :1 inch,Flow Rate :0.3-3 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173096049,"sku":"TFM\/NPT\/3\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-3-8-inch-end-connection-size-1-inch-flow-rate-0-3-3-us-gpm-25381837734001.png?v=1761752004"},{"product_id":"nuflo-liquid-npt-meter-line-size-1-2-inch-end-connection-size-1-inch-flow-rate-0-75-7-5-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :1\/2 inch,End Connection Size :1 inch ,Flow Rate :0.75-7.5 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173194353,"sku":"TFM\/NPT\/1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-1-2-inch-end-connection-size-1-inch-flow-rate-0-75-7-5-us-gpm-25381837799537.png?v=1761752003"},{"product_id":"nuflo-liquid-npt-meter-line-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-15-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :3\/4 inch ,End Connection Size :1 inch,Flow Rate :2-15 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173227121,"sku":"TFM\/NPT\/3\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-3-4-inch-end-connection-size-1-inch-flow-rate-2-15-us-gpm-25381837897841.png?v=1761752003"},{"product_id":"nuflo-liquid-npt-meter-line-size-7-8-inch-end-connection-size-1-inch-flow-rate-3-30-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :7\/8 inch ,End Connection Size :1 inch,Flow Rate :3-30 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173259889,"sku":"TFM\/NPT\/7\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-7-8-inch-end-connection-size-1-inch-flow-rate-3-30-us-gpm-25381838323825.png?v=1761752003"},{"product_id":"nuflo-liquid-npt-meter-line-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :1 inch,End Connection Size :1 inch,Flow Rate :5-50 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173292657,"sku":"TFM\/NPT\/1 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-1-inch-end-connection-size-1-inch-flow-rate-5-50-us-gpm-25381838422129.png?v=1761752003"},{"product_id":"nuflo-liquid-npt-meter-line-size-1-1-2-inch-end-connection-size-1-1-2-inch-flow-rate-15-180-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :1-1\/2 inch,End Connection Size :1-1\/2 inch ,Flow Rate :15-180 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173358193,"sku":"TFM\/NPT\/1-1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-1-1-2-inch-end-connection-size-1-1-2-inch-flow-rate-15-180-us-gpm-25381838553201.png?v=1761752002"},{"product_id":"nuflo-liquid-npt-meter-line-size-2-inch-end-connection-size-2-inch-flow-rate-40-400-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :2 inch,End Connection Size :2 inch,Flow Rate :40-400 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173423729,"sku":"TFM\/NPT\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-2-inch-end-connection-size-2-inch-flow-rate-40-400-us-gpm-25381838749809.png?v=1761752003"},{"product_id":"nuflo-liquid-npt-meter-line-size-3-inch-end-connection-size-3-inch-flow-rate-80-800-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :3 inch,End Connection Size :3 inch,Flow Rate :80-800 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173456497,"sku":"TFM\/NPT\/3 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-3-inch-end-connection-size-3-inch-flow-rate-80-800-us-gpm-25381839274097.png?v=1761751999"},{"product_id":"nuflo-liquid-npt-meter-line-size-4-inch-end-connection-size-4-inch-flow-rate-100-1200-us-gpm","title":"Nuflo Liquid NPT meter, Line Size :4 inch,End Connection Size :4 inch,Flow Rate :100-1200 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173489265,"sku":"TFM\/NPT\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-npt-meter-line-size-4-inch-end-connection-size-4-inch-flow-rate-100-1200-us-gpm-25381839339633.png?v=1761751999"},{"product_id":"nuflo-liquid-flanged-end-rf-meter-line-size-3-8-inch-end-connection-size-1-2-inch-flow-rate-0-3-3-us-gpm","title":"Nuflo Liquid Flanged end RF meter, Line Size :3\/8 inch,End Connection Size :1\/2 inch,Flow Rate :0.3-3 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173554801,"sku":"TFM\/FLANGED END\/3\/8 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-flanged-end-rf-meter-line-size-3-8-inch-end-connection-size-1-2-inch-flow-rate-0-3-3-us-gpm-25381839405169.png?v=1761751997"},{"product_id":"nuflo-liquid-flanged-end-rf-meter-line-size-1-2-inch-end-connection-size-1-2-inch-flow-rate-0-75-7-5-us-gpm","title":"Nuflo Liquid Flanged end RF meter, Line Size :1\/2 inch,End Connection Size :1\/2 inch,Flow Rate :0.75-7.5 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173587569,"sku":"TFM\/FLANGED END\/1\/2 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-flanged-end-rf-meter-line-size-1-2-inch-end-connection-size-1-2-inch-flow-rate-0-75-7-5-us-gpm-25381839470705.png?v=1761751998"},{"product_id":"nuflo-liquid-flanged-end-rf-meter-line-size-3-4-inch-end-connection-size-3-4-inch-flow-rate-2-15-us-gpm","title":"Nuflo Liquid Flanged end RF meter, Line Size :3\/4 inch,End Connection Size :3\/4 inch,Flow Rate :2-15 US GPM","description":"\u003cp\u003eCameron trademarked Nuflo GT Gas flowmeters and Nuflo LT Liquid flowmeters are used widely as a replacement of traditional meters which assists with the correct and specific measurement in oil and gas industry. Both brands are designed and developed with an aim to measure liquid and gas flow without any errors. Moreover, easily replaceable cartridges in both systems provide low-cost maintenance. Our company provides both Nuflo GT and Nuflo LT flowmeters word wide with fast shipping option. Feel free to contact us via the form below and we will get back to you as soon as possible.\u003c\/p\u003e\n","brand":"Nuflo","offers":[{"title":"Default Title","offer_id":42170173620337,"sku":"TFM\/FLANGED END\/3\/4 inch","price":0.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/3930\/0977\/files\/nuflo-turbine-flow-meters-default-title-nuflo-liquid-flanged-end-rf-meter-line-size-3-4-inch-end-connection-size-3-4-inch-flow-rate-2-15-us-gpm-25381839536241.png?v=1761751997"}],"url":"https:\/\/www.generaltechshop.sa\/collections\/measurement-flowmeters.oembed","provider":"General Tech Services LLC","version":"1.0","type":"link"}